Introduction

Horizontal offers a 600L chamber capacity for high-efficiency sterilization in laboratory environments. Operating within a temperature range of 105°C to 139°C, it ensures precise and consistent sterilization. Its built-in printer allows seamless monitoring and documentation of sterilization cycles. This autoclave delivers high performance, reliability, and ease of integration into modern sterilization facilities.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is specifically designed to sterilize items that are resistant to high temperatures and pressures, making it ideal for a wide range of materials.

Specifications

Chamber Capacity 600 Liters
Door Type Single Door
Control System + + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 35 kg
Water Consumption per Cycle 220 kg
Power Consumption 39 kW
Chamber Size (W × D × H) 652 × 690 × 1350 mm
Outer Dimensions (W × D × H) 1400 × 1950 × 1700 mm
Net Weight 1150 kg

Features

Large-Capacity Chamber

Durable Single-Door Configuration

Advanced + Control System 

Color Touchscreen Display

Stable Working Pressure Range

Automatic Safety Valve 

High-Temperature Operation 

Accurate Temperature Control 

Adjustable Sterilization and Drying Time Settings

Efficient Liquid Ring Vacuum System (Pre & Post Vacuum)

Optimized Steam and Water Usage per Cycle

High-Efficiency Power Consumption

Spacious Internal Chamber 

FAQs

1. What is the recommended sterilization cycle for different types of laboratory materials?

The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.

2. How to properly load the autoclave to ensure effective sterilization?

Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.

3. What maintenance procedures are required for the autoclave?

Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.

4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?

If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.

5. What safety precautions should be followed when operating the autoclave?

Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.

1. What is the chamber capacity of the Horizontal Laboratory Autoclave , and how does it benefit high-volume sterilization workflows?

The Horizontal Laboratory Autoclave is equipped with a 600-liter chamber, offering a spacious internal environment for sterilizing a wide range of instruments, including surgical tools, glassware, liquids, and porous loads. This large capacity makes it highly suitable for busy laboratories, research institutions, pharmaceutical companies, and hospital CSSDs, where high-throughput sterilization is essential. The generous chamber size allows users to process large batches in a single cycle, improving operational efficiency and reducing downtime.

2. How does the Horizontal Laboratory Autoclave ensure accurate and consistent sterilization performance?

The Horizontal Laboratory Autoclave operates within a precise temperature range of 105°C to 139°C, with temperature control accuracy of less than equal to ± 0.2°C and temperature display resolution of 0.1°C. It also features an impressive temperature equilibrium of less than equal to ± 0.5°C, ensuring that heat is evenly distributed throughout the chamber. This level of precision is crucial in achieving effective sterilization, especially for sensitive instruments and temperature-critical media.

3. What type of door configuration does the Horizontal Laboratory Autoclave have, and how does it contribute to safety and operational convenienc

The Horizontal Laboratory Autoclave comes with a durable single-door configuration. This design not only enhances structural integrity and pressure retention but also streamlines the loading and unloading process. The single door mechanism integrates seamlessly with automatic safety valves and pressure monitoring systems, minimizing user error and enhancing operational safety.

4. What makes the control system of the Horizontal Laboratory Autoclave user-friendly and advanced?

This Horizontal Laboratory Autoclave is built with an advanced + control system, paired with a 7.0-inch color touchscreen display. The interface allows intuitive navigation, real-time monitoring, and programmable cycle customization, including adjustable sterilization (0 to 999 min) and drying times (0 to 999 min). Additionally, the built-in printer ensures thorough documentation of every sterilization cycle, supporting traceability and compliance with laboratory protocols and quality standards.

5. How does the Horizontal Laboratory Autoclave manage steam and water consumption efficiently?

To optimize utility consumption, the Horizontal Laboratory Autoclave uses only 35 kg of steam and 220 kg of water per cycle, which is significantly efficient for a system of its size. Its efficient liquid ring vacuum system, capable of achieving a vacuum rate of –97 kPa, further enhances energy efficiency by reducing the total sterilization and drying time. This eco-conscious design helps laboratories maintain lower operational costs while ensuring top-tier sterilization results.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.