Introduction
Kjeldahl System offers digestion, distillation, and titration processes for streamlined analysis. They include automated reagent handling and real-time monitoring for increased efficiency and accuracy. Their fume extraction and waste neutralization technique ensure safer operations. They support real-time data logging for nitrogen and protein content to report findings. Our Kjeldahl System is ideal for environmental testing, pharmaceuticals and agricultural laboratories.
Kjeldahl Analyzer LKA-T2010
Kjeldahl Analyzer is capable to measure nitrogen content ranging from 0.1 mgN to 200 mgN, covering nitrogen concentrations from 0.1% to 99%. It features a microcomputer-controlled system...
Semi-T20utomatic Kjeldahl Analyzer LKA-T2010
Semi-Automatic Kjeldahl Analyzer features measuring range from 0.1 mg to 240 mg allow for the analysis of samples with varying quantities of nitrogen content. It analyzes with a capacity...
Fully Automatic Kjeldahl Analyzer LKA-T2013
Fully Automatic Kjeldahl Analyzer measures nitrogen in the 0.1 to 210 mgN range and delivers fast analysis within 4 to 6 minutes. It has a large control system for stability. The analyze...
Fully Automatic Kjeldahl Analyzer LKA-T2012
Fully Automatic Kjeldahl Analyzer is capable of measuring the nitrogen content in a range of 0.1mg to 240mg N. It can be paired with a 24-position autosampler for an advanced operation t...
Graphite Block Kjeldahl Digester LKGD-T2011
Graphite Block Kjeldahl Digester is an eco-friendly graphite block digester system with anti-corrosive design comprised of high temperature infrared radiation heating technology. Feature...
Graphite Kjeldahl Digester LKGD-T2010
Graphite Kjeldahl Digester is an eco-friendly graphite digester system with anti-corrosive design comprised of high temperature infrared radiation heating technology. Features 20 digesti...
Fully-T20utomatic Kjeldahl Analyzer LKA-T2011
Fully-automatic Kjeldahl Analyzer is a compact and fully automated unit, adopted with distillation and titration function based on classic Kjeldahl nitrogen determination method, offers ...
Semi-T20utomatic Kjeldahl Analyzer LKA-T2020
Semi-Automatic Kjeldahl Analyzer is equipped with advanced 4.3 inch screen, automatic fault detection system and intelligent audible and visual alarm system. With features such as automa...
Kjeldahl Analyzer LKA-T2010
Kjeldahl Analyzer is a complete microcomputer controlled user-friendly automatic device integrating distillation and titration functions. It is compatible with 42 mm digestion tubes and ...
Fully-T20utomatic Kjeldahl Analyzer LKA-T2010
Fully-automatic Kjeldahl Analyzer conducts titration and distillation simultaneously so as to neutralize the ammonia gas released which enhance the test efficiency and avoid the overflow...
Kjeldahl Digestion Unit T-KD-L2204
Automatic Kjeldahl Analyzer T-KD-L2203
Graphite Digestor T-KGD-S2101
Graphite Digestor T-KGD-S2100
Automatic Kjeldahl Analyzer T-KD-C202
Fully Automatic Kjeldahl Analyzer T-KD-C201
Automatic Kjeldahl Analyzer T-KD-L2202
Kjeldahl Analyzer T-KD-S2201
Automatic Kjeldahl Analyzer T-KD-L2201
Automatic Kjeldahl Analyzer KA20520
Automatic Kjeldahl Analyzer delivers fast and precise nitrogen analysis with a measuring range of 0.1 to 240mg N. It supports automated sample digestion to minimize any human error. Desig...
Standards
ISO 1871:2009-Food and feed products-General guidelines for the determination of nitrogen by the Kjeldahl method
Complies with the above standards, but is not limited to them.
Features
1. Tool-free glass assembly and disassembly speed changeover.
2. Data and timer options support method records.
3. Clear controls show temperature and time.
4. Cooling or condensation components recover vapours.
5. Clear method presets align with common analytical standards.
FAQ
What is the Kjeldahl System mainly used for?
The Kjeldahl System is used for a defined chemical preparation step such as digestion, extraction, evaporation or distillation. It supports analytical, environmental, food, pharmaceutical and teaching laboratories following standard procedures.
What standards does the Kjeldahl System comply with?
The apparatus is designed with reference to IEC 61010 electrical safety and relevant ISO and GB/T standard methods for the specific procedure. Glassware and heating must match the method. Compliance documentation can be provided on request.
How long is the warranty period?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
Will staff need special training?
Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Kjeldahl System need calibration or verification?
To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.
Where do we get replacement parts?
Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.
Are options or configurations available?
A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.
Do you provide on-site installation?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not use incompatible or damaged glassware, exceed temperature or pressure limits or work without ventilation for fuming samples. Follow the standard method and safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.