Horizontal features a wide working temperature range of 105°C to 139°C. With a design pressure of –0.1/0.5 MPa and a working pressure range of 0 to 0.25 MPa, it ensures safety and reliability. This autoclave includes a powerful liquid ring vacuum pump supporting both pre- and post-vacuum cycles. With a spacious internal chamber, it combines capacity, precision, and safety to meet demanding sterilization needs.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is suitable for sterilizing wrapped or unwrapped instruments, glassware, rubber materials, liquids, porous loads, and hollow instruments.

Specifications

Chamber Capacity 250 Liters
Door Type Double Door
Control System + + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 16 kg
Water Consumption per Cycle 120 kg
Power Consumption 22 kW
Chamber Size (W × D × H) 550 × 550 × 850 mm
Outer Dimensions (W × D × H) 1290 × 1850 × 1200 mm
Net Weight 750 kg

Features

Large Capacity

Double Door Design

Advanced Control System

User-Friendly Interface

High Precision Temperature Control

Wide Operating Range

Powerful Vacuum System

Flexible Cycle Timing

Efficient Performance

Robust Safety Mechanism

FAQs

1. What are the key advantages of using the Horizontal Laboratory Autoclave in a laboratory or research facility?

The Horizontal Laboratory Autoclave offers a range of benefits, including its wide working temperature range (105°C to 139°C) and high precision control system with an accuracy of ±0.2°C. It is equipped with a + control system and a 7.0-inch touchscreen, making operation user-friendly and programmable. Its dual-door design supports sterile workflow by preventing cross-contamination between loading and unloading areas. Additionally, the liquid ring vacuum pump ensures efficient pre- and post-vacuum sterilization, especially beneficial for porous and hollow items.

2. How does the dual-door feature of the Horizontal Laboratory Autoclave enhance operational safety and contamination control?

The double-door design of the Horizontal Laboratory Autoclave is particularly valuable in environments such as CSSDs (Central Sterile Services Departments) or clean labs. One door is for loading, and the other for unloading in a sterile zone, effectively preventing contamination between sterile and non-sterile zones. This feature ensures a unidirectional workflow, critical for maintaining hygiene standards in research, clinical, and industrial applications.

3. What makes the temperature control system of the Horizontal Laboratory Autoclave highly precise and reliable?

The Horizontal Laboratory Autoclave is engineered with high-precision temperature regulation capabilities. It features: • Temperature control accuracy of less than equal to ±0.2°C • Display accuracy of 0.1°C • Temperature equilibrium of less than equal to ±0.5°C This precision ensures consistent sterilization results, which is essential for sensitive materials and instruments that require exact conditions for validation and compliance.

4. Is the Horizontal Laboratory Autoclave suitable for sterilizing complex or delicate laboratory items?

Yes, the Horizontal Laboratory Autoclave is specifically designed to handle a wide variety of loads, including delicate glassware, hollow instruments, rubber materials, and liquids. Its powerful vacuum system allows complete air removal from complex internal geometries, ensuring deep penetration of steam for effective sterilization. Additionally, programmable sterilization and drying cycles (ranging from 0 to 999 minutes) make it adaptable for delicate items requiring controlled exposure times.

5. What type of control interface does the Horizontal Laboratory Autoclave offer, and how does it improve usability?

The Horizontal Laboratory Autoclave is integrated with a + system and a 7.0-inch color touchscreen display, offering an intuitive, easy-to-navigate interface. Users can easily program sterilization parameters, monitor temperature and pressure in real time, and review cycle records via the built-in printer. This modern interface enhances operational efficiency and documentation accuracy, crucial for -compliant laboratories and research environments.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.