Introduction
Ultrapure Water System operates within a temperature range of 5 °C to 40 °C. It features an advanced purification system with a durable all-plastic molded design. This intelligent unit delivers both analytical grade pure water and ultrapure water. It effectively removes organic and inorganic impurities, ensuring high purity and consistent water quality. Our ultrapure water produced is ideal for , IC, GC, and GC/MS applications requiring ultra-low organic content.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Ultrapure Water System is ideal for chromatography, molecular biology, clinical laboratories, analytical chemistry, , and electronics, delivering consistently high-purity water essential for accuracy, precision, reliability, and contamination-free applications.
Specifications
| Source | RO, Distilled, DI water |
| Conductivity | < 20 us/cm |
| Water Temperature | 5 ℃ to 40 ℃ |
| Class I Resistivity (25 ºC) | 18.2 MΩ.cm |
| Class I Water Conductivity (25 ºC) | 0.055 us/cm |
| Class I Water Total Organic Carbon Level | 1 to 5 ppb |
| Class I Flow Rate | 1.5 to 2.0 L/min |
| Class I Particulate Matter | < 1 pc/ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 HZ/60 HZ |
| External Dimension (Main Units) | 315 × 525 × 570 mm |
| External Dimension (Water Tank) | 380 × 380 × 595 mm |
| Net Weight (Main Units) | 18 Kg |
| Net Weight (Water Tank) | 5 Kg |
Features
Powerful Ion Exchange
Flexible Water Dispensing
High Purity Output
Dual-Stage Purification
Reliable and Low-Maintenance
FAQs
1. What type of water quality does the Ultrapure Water System provide?
The Ultrapure Water System delivers Type I ultrapure water with a resistivity of up to 18.2 M?·cm, making it ideal for highly sensitive applications. This high level of purity ensures minimal interference in analytical procedures. The produced water is free from particulates, organic contaminants, and microorganisms. It also meets stringent requirements for , conductivity, and endotoxin levels. The system is capable of producing both ultrapure and analytical-grade water. This makes it suitable for laboratories that demand consistent, high-quality water output. Additionally, the system continuously monitors purity to ensure stable and reliable performance over time.
2. Can the Ultrapure Water System be used for biological and pharmaceutical applications?
Yes, the Ultrapure Water System is well-suited for biological and pharmaceutical applications, including , cell culture, and / analysis. It can be equipped with optional UV and ultrafiltration modules to eliminate RNase, DNase, and pyrogens. These enhancements ensure the water meets the highest purity standards required for molecular biology. The system maintains bacterial levels below 0.1 /mL and levels as low as 1–5 ppb, ensuring contamination-free water. This is critical for achieving reliable and reproducible results in sensitive experiments. The system also complies with international laboratory water standards. Its performance remains stable even with extended daily use.
3. How does the Ultrapure Water System ensure consistent water quality over time?
The Ultrapure Water System ensures consistent water quality through dual-stage purification and real-time monitoring of key parameters. Indicators such as conductivity, resistivity, and are clearly displayed on the control panel for easy tracking. Advanced sensors detect any fluctuation in purity and alert users when maintenance is required. The system uses long-life purification cartridges to reduce replacement frequency and minimize downtime. Its design also reduces the risk of environmental contamination. Regular self-checks and alerts maintain system efficiency and stability. This ensures high reliability for all critical laboratory applications.
4. What feed water source is required for the Ultrapure Water System ?
The Ultrapure Water System is designed to operate with pretreated water such as reverse osmosis (RO), distilled, or deionized (DI) water. The feed water should have a conductivity below 20 µS/cm for optimal performance. Using low-quality feed water can shorten cartridge lifespan and negatively affect water purity. The system includes a built-in pre-filtration stage that helps protect core purification components. Regular monitoring of feed water quality is essential for maintaining consistent performance. In high-demand laboratories, a stable and clean feed water source ensures uninterrupted operation. This guarantees the production of ultrapure water for all sensitive applications.
5. Is the Ultrapure Water System user-friendly for lab personnel?
Yes, the Ultrapure Water System is designed with a strong focus on user convenience and simplicity. It features an intuitive touch-screen interface that displays all key performance indicators, including , resistivity, and conductivity. The system includes a remote water dispenser, providing easy access to ultrapure water without interrupting workflow. Built-in alerts and maintenance notifications keep users informed of system status at all times. The system is easy to install and requires minimal technical training for daily use. Its user-friendly design makes it ideal for laboratories with multiple users or rotating staff. Overall, it offers a smooth and efficient user experience.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.