Introduction

Horizontal offers a high-capacity of 300L, designed to meet the rigorous demands of laboratory and research facilities. It features a robust design with a vacuum rate of -0.081 MPa, supporting both pre-vacuum and post-vacuum phases. It includes a built-in steam generator, vacuum drying function, and a single-door configuration for streamlined operation. With durable construction, it is ideal for high-throughput environments requiring consistent performance and safety.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is specifically designed for sterilizing surgical instruments, laboratory glassware, and waste materials. Its high-capacity chamber and advanced vacuum system make it suitable for high-throughput environments.

Specifications

Capacity 300 L
Design Pressure -0.1 / 0.25 MPa
Max Working Pressure 0.23 MPa
Design Temperature 139°C
Working Temperature Range 105°C to 136°C
Temperature Accuracy ±0.1°C
Sterilization Time Range 0 to 99 min
Drying Time Range 0 to 99 min
Vacuum Rate -0.081 MPa
Door Type Single door
Control System + + Built-in Printer
Display 7-inch color touch screen
Vacuum System Pre-vacuum and post-vacuum
Steam Generator Built-in steam generator
Loading Type Sterilization tray
Water Tank Included
Drying Function Vacuum drying
Voltage 380V, 50/60Hz
Power Consumption 15 kW
Chamber Size 300L / Ø600 × 1080 mm
Outer Dimensions 1520 × 850 × 1850 mm
Packing Dimensions 1680 × 1080 × 2100 mm
Net Weight 580 kg
Gross Weight 680 kg

Features

High-Capacity Chamber

Advanced Control System

User-Friendly Interface

Pre and Post Vacuum System

Accurate Temperature Control

Built-in Steam Generator

Vacuum Drying Function

Robust Pressure Range

Efficient Power Consumption

Integrated Water Tank

Durable Construction

Optimized Loading System

FAQs

1. What are the key advantages of using the Horizontal Laboratory Autoclave in high-throughput laboratory or research settings?

The Horizontal Laboratory Autoclave offers multiple advantages tailored for demanding environments such as hospitals, research laboratories, and pharmaceutical facilities. Its large 300L capacity enables the sterilization of a substantial volume of materials in one cycle, improving operational efficiency. The built-in steam generator ensures rapid steam production, while the pre and post vacuum system enhances sterilization effectiveness by removing air pockets and aiding in quicker drying. Additionally, the autoclave is equipped with a -controlled interface, a 7-inch color touchscreen, and a built-in printer for data recording and traceability, all contributing to a user-friendly yet advanced sterilization solution.

2. How does the Horizontal Laboratory Autoclave maintain temperature precision throughout the sterilization process?

The Horizontal Laboratory Autoclave is engineered with precise temperature control technology, offering a high accuracy level of ±0.1°C. This is critical for sterilizing sensitive lab instruments and materials where even slight temperature deviations could impact sterility assurance. Its working temperature range of 105°C to 136°C allows it to meet diverse sterilization needs while the + system continuously monitors and adjusts temperature variables in real-time to maintain optimal conditions inside the chamber.

3. What vacuum capabilities does the Horizontal Laboratory Autoclave offer, and how do they benefit the sterilization cycle?

The Horizontal Laboratory Autoclave includes an advanced vacuum system with a vacuum rate of -0.081 MPa, supporting both pre-vacuum and post-vacuum phases. The pre-vacuum phase removes trapped air from the chamber and materials, allowing steam to penetrate deeply and evenly. The post-vacuum phase accelerates drying by removing residual moisture, making it ideal for delicate instruments and wrapped items. These features not only improve sterilization outcomes but also reduce cycle times and energy consumption.

4. What control and monitoring systems are integrated into the Horizontal Laboratory Autoclave ?

To ensure reliable and safe operation, the Horizontal Laboratory Autoclave is outfitted with a -based control system paired with an (Human Machine Interface) and a 7-inch color touchscreen display. This intuitive interface allows operators to set, monitor, and adjust parameters such as temperature, pressure, sterilization time, and drying time with precision. Additionally, the built-in printer automatically logs cycle data, enhancing traceability and compliance with laboratory and hospital sterilization standards.

5. What types of items can be sterilized using the Horizontal Laboratory Autoclave ?

The Horizontal Laboratory Autoclave is versatile and capable of sterilizing a wide range of materials commonly used in medical and research environments. These include surgical instruments, glassware, textiles, biohazard waste, and laboratory tools. Its high-capacity chamber and uniform heat distribution ensure consistent sterilization, while the vacuum drying system is especially useful for porous materials and items that must remain dry post-sterilization.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.