Introduction

Biochemical Incubator has an 800L capacity and a temperature range of 0°C to 60°C, making it ideal for both cooling and heating applications. The incubator includes an air duct system for even temperature distribution and a protection system to ensure safe and reliable operation. This biochemical incubator offers adjustable shelves for flexible storage. It also has 304 mirror-finish stainless steel interiors with rounded corners for easy cleaning and maintenance.

It provides a stable and controlled environment for cell culture, microbial growth, and other biological experiments. The precise temperature and humidity control ensure consistent experimental conditions and reliable results.

Applications

Biochemical Incubator is used in research and production for environmental protection, disease control, agriculture, aquaculture, and cell culture.

Specifications

Capacity 800L
Temperature Range 0 to 60°C
Temperature Fluctuation High Temp ±0.5°C, Low Temp ±1.0°C
Temperature Uniformity ±1.5°C
Refrigeration System fully enclosed compressor
Controller Microcomputer controller
Dual Protections Independent over-temperature protection system, with light
Shelf 4
Ambient Temperature +5 to 35°C
Interior Material Mirror surface Stainless Steel 304
External Material Steel powder coated
Voltage Supply AC 220V ±10% 50Hz
Safety Device Compressor and blower overheat protection, over-temp, overpressure & overload
Maximum Power 1.5 kW
Interior Dimensions 1200 × 490 × 1360 mm
External Dimensions 1390 × 900 × 1970 mm
Packaging Dimension 1430 × 970 × 2100 mm
Gross Weight 395 Kg

Features

Internal light

Low noise operation

Fully enclosed compressor  

Microcomputer temperature controller 

FAQs

1. How to calibrate the temperature and humidity controls in the laboratory incubator?

Calibration should be performed by qualified personnel using calibrated temperature and humidity sensors: 1) Place the calibrated sensors at different locations inside the incubator chamber to ensure uniform distribution; 2) Set the incubator to the desired temperature and humidity levels and allow it to stabilize for at least 24 hours; 3) Compare the readings from the incubator's display with the calibrated sensors; 4) Adjust the controls according to the manufacturer's instructions if discrepancies are found; 5) Document the calibration results and schedule regular recalibration (every 6-12 months).

2. What is the optimal way to arrange samples inside the incubator for uniform conditions?

To ensure uniform conditions: 1) Avoid overcrowding the incubator, leaving sufficient space between samples for air circulation; 2) Place samples away from the chamber walls, heating/cooling elements, and door to prevent temperature fluctuations; 3) Use shelves or racks that allow air to circulate freely around all samples; 4) Avoid placing large or heat-generating equipment inside the incubator; 5) Rotate samples periodically if long-term incubation is required to account for any minor temperature variations.

3. Can the incubator be used for anaerobic or CO2-enriched environments?

Specialized incubators (anaerobic incubators, CO2 incubators) are designed for these environments. Standard incubators may not maintain the required gas concentrations or oxygen-free conditions. For anaerobic applications, use an incubator equipped with a gas control system that maintains oxygen levels below 1% and may include catalysts to remove oxygen. For CO2-enriched environments, use a CO2 incubator that maintains precise CO2 concentrations (typically 5-10%) and humidity levels, essential for cell culture applications.

4. How to clean and disinfect the incubator to prevent contamination?

Regular cleaning and disinfection steps: 1) Turn off the incubator and allow it to cool down to room temperature; 2) Remove all samples and shelves; 3) Wipe the interior surfaces with a mild detergent solution, followed by a disinfectant compatible with the incubator materials (such as 70% ethanol); 4) For stubborn contamination, use a specialized laboratory disinfectant according to the manufacturer's instructions; 5) Clean the shelves and any accessories separately; 6) Allow all surfaces to dry completely before reassembling and restarting the incubator; 7) Perform this procedure monthly or more frequently if contamination is suspected.

5. What should be done if the incubator temperature fluctuates significantly?

If temperature fluctuations occur: 1) Check if the incubator door is properly closed and sealed; 2) Ensure the incubator is not placed near heat sources, air conditioning vents, or drafty areas; 3) Verify that the incubator is not overloaded, which can restrict air circulation; 4) Check the air filter (if equipped) and replace it if dirty; 5) Inspect the heating and cooling elements for proper operation; 6) If the problem persists, contact technical support for further diagnosis and repair, as it may indicate a malfunction in the temperature control system.

1. What is the temperature range and capacity of the It Biochemical Incubator , and how does it support both heating and cooling application

The It Biochemical Incubator offers a wide temperature range from 0°C to 60°C, making it suitable for both cooling and heating requirements in laboratory settings. It has a large internal capacity of 800 liters, providing ample space for storing multiple samples or culture media. This versatile temperature range allows it to be used for various temperature-sensitive applications like microbial incubation, environmental testing, and biochemical research. The unit maintains temperature stability through its microcomputer controller and dual protection system, ensuring consistent performance.

2. What features make a safe and reliable option for laboratory use?

It has equipped the incubator with multiple safety and protection features to ensure both user and sample safety. It includes an independent over-temperature protection system with alarm lighting to prevent overheating. Additionally, it features compressor and blower overheat protection, as well as safeguards against overpressure and overload. These built-in safety systems help maintain equipment reliability and reduce the risk of damage or experimental error, making it a dependable choice for sensitive lab processes.

3. How does the It ensure even temperature distribution inside the chamber?

To maintain uniform conditions throughout the chamber, the It Biochemical Incubator is designed with an advanced air duct system. This system circulates air efficiently, ensuring that temperature is evenly distributed from top to bottom and across all corners. The temperature uniformity of ±1.5°C ensures that all stored samples are exposed to consistent conditions, which is especially important for cell culture and microbial growth experiments.

4. What construction and design elements of the make it user-friendly and easy to maintain?

The It is designed with practicality and durability in mind. Its interior is made from 304 mirror-finish stainless steel, which is corrosion-resistant and easy to clean. The rounded interior corners further simplify maintenance by preventing residue buildup. Adjustable shelves allow users to customize the internal layout based on their storage needs. Additionally, the external structure is powder-coated steel, offering both robustness and aesthetic appeal. These thoughtful design features make routine use and cleaning straightforward for lab personnel.

5. What are the main applications of the It Biochemical Incubator in scientific and industrial fields?

The It Biochemical Incubator is widely used across various fields including environmental protection, disease control, agriculture, aquaculture, and cell culture research. It provides the controlled temperature environment necessary for cultivating bacteria, fungi, and cells, as well as for stability testing of products. Its large volume, precise temperature control, and safety features make it ideal for research institutions, quality control labs, pharmaceutical industries, and biotech companies involved in product development and testing.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.