Introduction
A touchscreen pH meter is a pH meter with the touchscreen interface, used to measure the pH of the solutions, and it is used in the laboratories, the water treatment, the environmental monitoring, the food, and the many other applications. The touchscreen pH meter measures the pH by the measurement of the potential difference between the pH electrode and the reference electrode, and it provides the pH value, with the automatic temperature compensation; the touchscreen pH meter consists of a meter with the touchscreen display, a pH electrode, a temperature sensor, and the controls, and it provides features such as the calibration, the automatic temperature compensation, and the data management; the touchscreen pH meter is used for the measurement of the pH of the water, the wastewater, the foods, the beverages, and the other solutions, for the quality control, for the monitoring, for the research, and for many other applications, and it is available as the benchtop and the portable models; the touchscreen pH meter is an essential instrument for the pH measurement. Touchscreen pH meters are used in the laboratories, in the water treatment, in the environmental monitoring, in the food industry, and for many other applications. With their touchscreen interface, touchscreen pH meters are essential for the convenient pH measurement.
Touchscreen PH Meter LTSPM-T2010
Touchscreen pH Meter is a bench-top design that measures the hydrogen ion concentration of various samples. It offers pH measuring range of -2.00 to 20.00 pH with an accuracy of ± 0.002...
Standards
GB/T 11165-2005-Laboratory pH meter
USP General Chapter <791>-pH
IEC 60746-2:2003-Expression of performance of electrochemical analyzers-Part 2: pH value
Complies with the above standards, but is not limited to them.
Features
1. Touchscreen pH meter for high-accuracy measurement of acidity/alkalinity with intuitive color touchscreen interface.
2. Advanced benchtop or portable pH analyzer with graphical display, multi-point calibration, data logging and GLP support.
3. Suitable for pharmaceutical, food and beverage, chemical, water treatment, environmental and research laboratories.
4. Includes meter body, pH electrode, temperature probe, calibration buffers, power supply and operation manual.
5. Supports pH, mV/ORP and temperature measurement with automatic temperature compensation and advanced data management.
FAQ
Q1: What testing scenarios is this meter mainly applied to?
A: The touchscreen pH meter is used in pharmaceutical, food and beverage, chemical, water treatment, environmental, and research laboratories for high-accuracy pH measurement of aqueous solutions and semi-solids, with the convenience of a color touchscreen interface for easy method setup, calibration, data review, and regulatory compliance (GLP/GMP). It supports pharmaceutical (quality control (pH of APIs, formulations, buffers, purified water, WFI - per USP <791>, EP 2.2.3), research and development (formulation, reaction monitoring, dissolution testing), cleanroom and GMP environments (user login, audit trail, calibration records for 21 CFR Part 11)), food and beverage (brewing (mash pH, wort, beer - affects enzyme activity, flavor, microbial stability per ASBC), wine (must, wine pH - fermentation, color, stability per OIV), dairy (milk, cheese, yogurt - process control, quality), soft drinks/juices (pH for taste, preservation, product specification), chemical (solution preparation, reaction monitoring, neutralization, plating baths, wastewater, process control), water treatment (drinking water (pH 6.5-8.5 per WHO/EPA, corrosion control), wastewater (influent/effluent pH 6-9 per discharge limits, neutralization), boiler/cooling water), environmental (rivers, lakes, groundwater, rainwater (acid rain), soil pH (slurry), stormwater), and research/education (general chemistry, biochemistry, cell culture media (pH 7.0-7.4), buffer preparation, academic labs). Touchscreen interface provides: intuitive calibration (graphical calibration curves, slope/offset display), method storage (recall methods for different sample types), data logging (stored measurements with time/date/operator/calibration info), GLP/GMP compliance (user ID, password, audit trail, calibration records, data export via USB/Ethernet), and on-screen help. Higher accuracy than basic meters (typically +/- 0.002 to +/- 0.01 pH, resolution 0.001 pH) with multi-point calibration (up to 5-6 points) for demanding applications.
Q2: What standards does the meter comply with?
A: The touchscreen pH meter follows relevant ISO, ASTM, IUPAC, USP/EP, FDA and GB/T standards including ISO 10523 (water quality - determination of pH), ASTM D1293 (standard test methods for pH of water), IUPAC recommendations for pH measurement, USP <791> (pH - pharmacopeial method), EP 2.2.3 (potentiometric determination of pH), AOAC methods (food/dairy), ASBC/MEBAK (brewing), OIV (wine), FDA 21 CFR Part 11 (electronic records/signatures - if used in GMP), and GB/T standards for pH meters. The hardware complies with applicable analytical instrument standards (pH accuracy +/- 0.002 to +/- 0.01, resolution 0.001), EMC (IEC 61326), and safety (IEC 61010 for lab equipment). Calibration uses certified pH buffer solutions (pH 1.68, 4.01, 6.86/7.00, 9.18/10.01, 12.45 at 25 degrees C, traceable to national standards) per ISO 10523/ASTM D1293. For pharmaceutical use, follow USP <791> and cGMP (21 CFR Part 211), with equipment qualification (IQ/OQ) and 21 CFR Part 11 compliance if electronic records. For food/beverage, follow AOAC/ASBC/OIV methods. For regulated labs, follow ISO 17025 and maintain calibration records. Touchscreen meters with data logging and user management are designed for GLP/GMP compliance (calibration records, audit trail, user access).
Q3: What is the warranty period for the whole meter and key components?
A: The whole touchscreen pH meter is covered by a 12-24 month warranty (analytical instruments often 2 years; some 3 years). The meter body, touchscreen display, electronics, and temperature sensor are covered, while pH electrode (wear part - glass bulb fragile, reference junction clogs/fouls; lifespan 6-24 months depending on use/sample type; replaceable), calibration buffers (consumable - expire, absorb CO2), storage solution (3 M KCl), and power supply are consumables/accessories. Damage from improper use, electrode breakage (glass bulb - do not drop, scrape, touch with fingers; very fragile), dry storage (pH electrode MUST be stored wet - drying damages reference junction and glass hydration layer = permanent drift/failure), probe fouling (protein, scale, biofilm - clean regularly), using wrong/contaminated buffers, liquid ingress into meter, dropping, touchscreen damage (scratches, impact), or unauthorized repair is excluded. Extended warranty and service contracts (calibration, electrode replacement) may be available. Electronics/touchscreen last 5-10 years; pH electrode needs replacement every 6-24 months (sooner if response slow, drifts, cannot calibrate, slope <90%, or bulb cracked).
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is straightforward with touchscreen interface (menus, prompts, on-screen help). No professional training required for basic measurement, but proper calibration and electrode care are critical for accuracy (pH electrode is the most error-prone component). We provide operation manuals and on-screen guidance. Proper setup (connect power, turn on, allow warm-up (15-30 min for stabilization), connect pH electrode and temperature probe (ATC), allow electrode to equilibrate (if stored dry or new: soak in storage solution or pH 4 buffer for 1-24 hours to rehydrate - but try to never let dry), prepare calibration buffers (fresh buffers at measurement temperature; select buffers spanning expected sample pH (e.g., pH 4, 7, 10 for general; 2-5 point calibration for high accuracy); do not reuse buffers (absorb CO2, contaminated)), calibration via touchscreen (navigate to calibration menu, select buffers (meter auto-detects common buffers), rinse electrode with DI water, blot dry (lint-free tissue, gentle - do not rub), immerse in first buffer (usually pH 7), stir gently, wait for stable reading (30-60 sec), confirm; repeat for additional buffers (4, 10, etc.); touchscreen displays calibration curve, slope (should be 95-105% or 54-60 mV/pH at 25 C), offset (pH 7 reading within +/- 0.3), and date; save calibration (stored in memory with GLP data); if slope <90% or >105%, electrode needs cleaning/replacement), sample measurement (select method (or use general), rinse electrode with DI then sample water (avoid buffer carryover), blot, immerse in sample (ensure glass bulb and reference junction fully submerged, no air bubbles), stir gently (consistent speed), wait for stable reading (30-60 sec; slow = electrode fouling/aging), touchscreen displays pH, temperature, mV, stability indicator; save/record measurement (stored with time/date, operator, calibration info - GLP), for semi-solids/soil (use spear-tip electrode or make slurry (soil:water = 1:1 or 1:2.5, stir, settle, measure supernatant), for viscous samples (rinse promptly, use appropriate electrode), post-measurement (rinse electrode thoroughly with DI water (remove sample residue), clean if fouled (general: DI rinse; protein: pepsin/HCl or enzyme cleaner; grease/oil: mild detergent or methanol; scale/mineral: soak in 0.1 M HCl or vinegar; do NOT use abrasive on glass bulb), store electrode in storage solution (3 M KCl) or pH 4 buffer (NEVER store dry or in DI water - DI leaches KCl from reference, damages junction), maintenance (daily: rinse after use, check calibration (single-point with pH 7 before use), weekly: clean electrode (if food/industrial use - high fouling), inspect bulb (cracks, discoloration), monthly: full multi-point calibration, replace buffers, electrode rejuvenation (if sluggish: soak in 0.1 M HCl 1 hour, then storage solution; or warm (50 C) storage solution; if still slow, replace electrode), touchscreen care (clean with soft cloth, no abrasive solvents; do not press with sharp objects), troubleshooting (readings unstable/drifting (electrode fouled (clean), reference junction clogged (soak/rejuvenate), electrode aging (replace), low battery/power, temperature fluctuation - clean, rejuvenate, replace, control temp), readings too high/low (calibration error (wrong buffer, contaminated buffer, temp mismatch), electrode not equilibrated, junction clogged, sample CO2 exchange (alkaline samples absorb CO2 -> lower pH; measure promptly, minimize exposure), ATC off - recalibrate with fresh buffers, equilibrate, enable ATC, measure promptly), electrode not responding (bulb cracked (replace), dry (rehydrate 24h, but may be permanently damaged), cable/connector loose, meter fault - inspect, rehydrate, check cable, service), calibration fails (buffers expired/contaminated, electrode bad (slope <90%), temperature wrong - use fresh buffers, replace electrode, control temp), touchscreen unresponsive (frozen, dirty screen, calibration issue - clean screen, restart, recalibrate touchscreen per manufacturer), and safety (ELECTRODE HAZARD (glass bulb fragile and sharp if broken - handle carefully, do not touch bulb, use probe guard; broken glass = cut hazard; dispose properly), CHEMICAL (calibration buffers (mild acids/bases, low hazard but avoid ingestion/eye contact; wear PPE for concentrated solutions), cleaning solutions (HCl, detergents - handle per SDS), samples (wastewater, chemicals, food - wear gloves, eye protection; acidic/basic samples can burn), WATER/ELECTRICAL (benchtop near water - do not spill on meter, ensure proper grounding; do not immerse meter body (only electrode)), do not store electrode dry (permanent damage - always wet storage), do not use abrasive on glass bulb (scratches = inaccurate), for food/pharma: ensure electrode is food-grade/cleanable (stainless steel body, no crevices), cross-contamination (rinse thoroughly between samples, especially food/chemical), for GMP: follow SOPs, document calibration/use, maintain user access/audit trail for 21 CFR Part 11) are important for accurate pH measurement.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Calibration recommended: single-point check (pH 7) before each use or at start of day; full multi-point calibration (2-5 points) every 1-7 days depending on use (GMP/pharma/food = daily or before each batch; clean research lab = weekly/monthly). If electrode is cleaned, replaced, meter dropped, or readings seem off, recalibrate immediately. Routine verification: check with a buffer different from calibration buffers (e.g., calibrate 4/7, verify with 10) periodically. For ISO 17025/GMP/pharma labs, follow applicable schedules and maintain records (calibration certificates, buffer lot numbers, slope/offset, as-found/as-left data, electrode ID, user/operator). For pharmaceutical use per USP <791>, calibrate before each use with at least 2 buffers bracking sample pH, and verify with a third buffer. pH electrodes drift over time and with fouling - regular calibration is essential. Always use fresh, temperature-equilibrated buffers; do not reuse buffer (CO2 absorption and contamination change pH). Electrode slope (95-105%) is a key indicator of electrode health - if slope degrades, clean or replace. Touchscreen meters store calibration history for GLP compliance and can alert when calibration is due.
Q7: Are supporting consumables universal?
A: pH electrode (replacement - specific to meter brand/model (BNC connector is somewhat universal, but proprietary connectors exist; gel-filled vs refillable, glass vs spear; use OEM or certified compatible with correct connector), calibration buffers (pH 1.68, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45 - universal from lab supply (Mettler, Hach, Hanna, Ricca) but use certified traceable; do not mix brands if meter has specific expectations), storage solution (3 M KCl - universal, can be lab-prepared), cleaning solutions (mild detergent, 0.1 M HCl, enzyme cleaner - universal), power supply (specific to model), and electrode storage caps are available from lab supply companies, though electrodes and power supplies are often meter-specific (use OEM or certified compatible to maintain accuracy and warranty). Long-term consumable cost includes electrode replacement (periodic, $100-$500+) and calibration buffers (regular purchase).
Q8: Can I customize parameters or supporting accessories?
A: Customization includes electrode type (general glass bulb (water, solutions), spear tip (food, meat, soil - penetrates semi-solids), flat surface (paper, skin, surfaces), micro (small volumes, test tubes, well plates), refillable (repairable, longer life, but needs KCl refill) or gel-filled (low maintenance, convenient), heavy-duty/industrial (stainless steel body, for harsh conditions), high-temperature (for hot samples up to 100+ degrees C), low-ionic-strength (for pure water/UPW - fast response, flowing junction), fluoride-resistant (for samples with HF)), parameters (pH only, or pH + ORP (mV) + temperature, or multi-parameter (add conductivity, DO, ion concentration (ISE for Na+, K+, NH4+, etc.))), form factor (benchtop (lab, high accuracy, more features, power supply) or portable/field (battery, rugged, IP67 - though touchscreen is more common on benchtop)), display/interface (color touchscreen (size 3.5-7 inch), graphical calibration curves, method storage, data logging (1000-10000+ points), USB/Ethernet/WiFi/Bluetooth export, PC software, LIMS integration, GLP/GMP compliance (user ID/password, audit trail, electronic signatures, 21 CFR Part 11), alarms (calibration due, out-of-range), multi-language), accessories (extra electrodes (various types), calibration buffer kit (multiple values), storage solution, cleaning solutions, electrode stand (benchtop), stirrer (magnetic stirrer for consistent stirring), printer, spare power supply, validation/calibration certificate (ISO 17025), IQ/OQ package (for pharma/GMP), certifications (CE, FCC, ISO 9001, USP <791> compliance, 21 CFR Part 11), language and accessories. Additional electrodes, buffers, and accessories can be ordered separately.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes touchscreen pH meter, pH electrode, temperature probe, calibration buffers (initial), power supply, electrode stand, and instruction manual. On-site installation is not required for standard benchtop meters (unbox, assemble stand, connect electrode, calibrate, use). On-site training is not included for standard orders but can be arranged at additional cost (for GMP/pharma teams on IQ/OQ, 21 CFR Part 11 compliance, electrode maintenance, SOP development). Remote guidance provided. For GMP/pharma use: IQ/OQ (installation/operational qualification) and validation can be arranged. Always calibrate with fresh buffers before use.
Q10: What types of samples are compatible with this equipment?
A: The touchscreen pH meter measures pH of various aqueous and semi-solid samples including water (drinking, wastewater, natural (river, lake, groundwater), process, boiler, cooling, aquaculture), food and beverage (beer, wort, wine, must, juice, milk, cheese, yogurt, sauce, dough (with spear electrode), meat (with spear)), chemical solutions (acids, bases, salts, buffers, plating baths, cleaning solutions (CIP)), agriculture (soil (slurry or direct with spear), irrigation water, hydroponic nutrient solution), environmental (rainwater, stormwater, soil, sediment slurry), biological/culture media (cell culture media, fermentation broths, microbiological media, protein solutions), and pharmaceutical (APIs, formulations, buffers, purified water, WFI, dissolution media). NOT compatible with: Non-aqueous liquids (oils, solvents, pure organic - pH electrode requires aqueous hydration; may damage reference; use non-aqueous pH electrode if needed), highly viscous samples without proper electrode (can clog junction - use spear/large-junction electrode, clean promptly), samples with high fluoride (>1 ppm at low pH - etches glass bulb; use fluoride-resistant electrode), strong acids/bases beyond electrode range (pH <1 or >13 may damage glass/reference - verify range; concentrated acids/bases need special electrodes), samples that attack electrode materials (verify compatibility of glass, reference (Ag/AgCl), and body (epoxy/glass) with sample; proteins clog junction (use protein-resistant or refillable electrode), sulfides poison Ag/AgCl reference (use double-junction electrode), hydrofluoric acid (etches glass - use special electrode), and low-conductivity pure water (UPW, DI) without special electrode (standard electrodes give slow/unstable readings in pure water; use low-ionic-strength/flowing-junction electrode). IMPORTANT: Touchscreen pH meter fundamentals: (1) What is pH? pH = -log[H+] (activity of hydrogen ions). Scale 0-14: <7 acidic, 7 neutral, >7 basic. Logarithmic: pH 5 is 10x more acidic than pH 6. Temperature affects pH (neutral point shifts: 25 C = 7.00; 0 C = 7.47; 100 C = 6.14 - pure water is always neutral but pH value changes with temp). (2) How pH electrode works: Combination electrode = measuring (glass) electrode + reference electrode in one body. Glass bulb (thin, H+-sensitive membrane) develops potential proportional to pH difference between inside (fixed buffer) and outside (sample). Reference electrode (Ag/AgCl in KCl) provides stable reference potential through porous junction (KCl leaks into sample). Meter measures voltage difference and converts to pH via Nernst equation: E = E0 - (2.303RT/F) x pH. Slope at 25 C = 59.16 mV/pH. (3) Touchscreen advantages: - Intuitive operation (menus, icons, prompts) - less training. - Graphical calibration (visual curve, slope/offset). - Method storage (recall settings for different sample types). - Data logging (measurements with metadata - time, date, operator, calibration info). - GLP/GMP compliance (user login, audit trail, calibration records, electronic signatures). - On-screen help/tutorials. - Connectivity (USB, Ethernet, WiFi, LIMS). - Higher accuracy/resolution (0.001 pH) than basic meters. (4) Calibration: pH is operational - calibrated with standard buffers. - 2-point: pH 7 (zero/offset) + pH 4 or 10 (slope). - 3-5 point: 4, 7, 10 (and 1.68, 12.45 for extreme pH) - best accuracy. - Buffers must be at known temperature (pH of buffers changes with temp; meter with ATC and buffer tables corrects). - Slope should be 95-105% (56-62 mV/pH at 25 C). <90% = electrode aging/fouling. - Offset (pH 7 reading) within +/- 0.3 pH. (5) Key error sources: - Electrode condition (biggest): fouling, dry storage, cracked bulb, clogged junction, aging. - Calibration: expired/contaminated buffers, wrong temp, insufficient points. - Junction: KCl leakage must be continuous; clogged = unstable. - Temperature: ATC corrects electrode slope, but sample pH itself changes with temp (report temp). - CO2 exchange: alkaline samples absorb CO2 -> pH drops; measure quickly. - Stirring: affects equilibrium (stir consistently). - Static: low-conductivity samples (pure water) cause static -> unstable; use special electrode. (6) Electrode storage: - Store in 3 M KCl (storage solution) or pH 4 buffer. - NEVER store dry (dries reference junction and glass hydration layer = permanent damage, slow response, drift). - NEVER store in DI water (leaches KCl from reference, junction problems). - For long-term (>1 week): fill storage cap with solution, ensure bulb submerged. (7) Cleaning: - General: DI water rinse. - Protein (food, biological): pepsin in 0.1 M HCl or enzyme cleaner, soak 15-30 min. - Oil/grease: mild detergent or methanol, soak. - Mineral/scale: 0.1 M HCl or vinegar, soak 15 min. - Reference junction clog: soak in warm (50 C) KCl or KCl + 0.1 M HCl. - Do NOT use abrasive (scratches glass bulb). - After cleaning: soak in storage solution 1-2 hours before use (rehydrate). (8) Common pH values: - Stomach acid: 1.5-3.5 - Lemon juice: 2.0 - Vinegar: 2.4 - Cola: 2.5 - Wine: 3.0-3.8 - Beer: 4.0-4.5 - Coffee: 5.0 - Milk: 6.5-6.8 - Pure water: 7.0 (at 25 C) - Blood: 7.35-7.45 - Seawater: 8.0-8.3 - Baking soda solution: 8.3 - Ammonia: 11.0 - Bleach: 12.5 (9) When to replace electrode: - Slope <90% after cleaning/rejuvenation. - Response time >2-3 minutes (should be <30-60 sec). - Cannot calibrate (offset >0.5 pH). - Cracked/damaged bulb. - Drifting readings that do not stabilize. - Reference junction visibly clogged/damaged.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.