Introduction

Jacketed Glass Reactor features a 2 chemical processes. The stable frame design provides firm support, reducing vibrations during high-speed stirring. Its circulation jacket ensures steady heat distribution across the chamber for reliable thermal control. Our Glass Reactor is suited for concentration, and synthesis in pharmaceutical and academics.

This laboratory glass reactor is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Jacketed Glass Reactor  is ideal for controlled chemical synthesis and concentration tasks in pharmaceutical, academic, and research laboratories, providing precise temperature regulation and uniform heat distribution for small-scale reactions. 

Specifications

Glass Vessel Volume 2 L Cylindrical
Glass Vessel Lid Diameter Φ 150 mm
Jacketed Volume 250 ml
Dropping Funnel 250 ml
Temperature Range -80℃ to 250 ℃
Temperature Measurement Accuracy +/-1℃
Stirring Speed 0 to 450 rpm
Vacuum Degree 0.0098 Mpa
Power Consumption 40 W
Power Supply 220V/50Hz
Condenser Dimension (D×H) 40×350 mm
Dimensions (W×D×H) 330×350×1300 mm
Weight 18.5 kg

Features

Multi-angle condenser orientation

Leak-resistant joint seals

Corrosion-proof metal clamps

-coated stirring rod

Transparent chamber for visibility

FAQs

1. What advantages does the double-layer jacket provide in the Jacketed Glass Reactor?

The Jacketed Glass Reactor features a double-layer jacket design that enables accurate temperature regulation by circulating fluids around the vessel. The two jacket layers create a stable thermal environment essential for both heating and cooling, which supports a wide range of chemical processes. This design also keeps the circulating fluid separate from the reaction mixture, preventing contamination and preserving sample integrity. Maintaining consistent temperatures improves reaction reproducibility, while the jacket’s insulation reduces heat loss, enhancing energy efficiency during experiments.

2. How does the fixed external loop buffer enhance safety and reliability in the Jacketed Glass Reactor?

The fixed external loop buffer on the Jacketed Glass Reactor provides a secure connection for the circulation system, minimizing the chances of leaks during operation. It stabilizes fluid flow and prevents sudden pressure changes that could disturb reaction conditions. This is particularly important when operating under vacuum or with volatile substances, as it maintains system stability throughout long experimental runs. The robust design also lowers maintenance needs, ensuring dependable and safe performance for various applications.

3. Is the Jacketed Glass Reactor suitable for handling corrosive substances, and what materials ensure this?

The Jacketed Glass Reactor is constructed with high-quality borosilicate glass (type 3.3), which offers excellent resistance to thermal shock and chemical corrosion, making it appropriate for aggressive reagents. Its sealing system uses and fluororubber double seals that provide airtightness and leak prevention, even when working with harsh chemicals. These materials protect the reactor’s integrity during demanding procedures, extending its lifespan and minimizing contamination risks. This makes the reactor well-suited for pharmaceutical, petrochemical, and biochemical research.

4. How does the Jacketed Glass Reactor maintain vacuum conditions during experiments?

This reactor is designed to achieve and sustain high vacuum levels by using and fluororubber double seals that prevent air leakage and maintain pressure consistency. The borosilicate glass vessel is robust enough to withstand external pressure without deformation, ensuring reliable vacuum operation. This capability is essential for applications such as distillation, drying, and handling sensitive compounds where controlled atmospheres are required. Maintaining vacuum conditions reduces contamination risk and broadens the scope of possible experimental techniques.

5. What benefits does the dropping funnel offer in the Jacketed Glass Reactor?

The integrated dropping funnel in the Jacketed Glass Reactor allows for controlled, gradual addition of reagents directly into the reaction vessel. This helps avoid sudden concentration changes that could lead to unwanted side reactions or temperature spikes. The funnel also limits exposure to air, which helps preserve reaction purity and safety. It enables continuous operation without needing to stop the process, which is critical for careful synthesis and distillation workflows. Overall, the dropping funnel enhances reaction control and improves yield.

6. How do the condenser dimensions impact the performance of the Jacketed Glass Reactor?

The condenser’s size and shape in the Jacketed Glass Reactor are optimized to maximize vapor condensation during reflux. Its length and surface area provide effective heat exchange while maintaining a compact footprint suitable for lab settings. Efficient condensation helps recover and recycle solvents, reducing loss and cutting costs. This feature supports longer reaction times by maintaining solvent volume and concentration. The condenser also contributes to stable reaction conditions by controlling vapor dynamics throughout the process.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.