Introduction
Pilot Standard Freeze Dryer features a condenser temperature of -35°C, ensuring efficient freeze-drying for sensitive materials. The built-in vacuum gauge enables accurate pressure tracking to preserve product structure during sublimation. Offers a real-time display system that provides live process updates, allowing timely adjustments. Our freeze dryer is widely used in food testing and research labs handling small-scale tasks.
This laboratory freeze dryer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Pilot Standard Freeze Dryer gently removes moisture from samples using low-temperature sublimation, preserving structure and composition. It is widely used across research laboratories, pharmaceutical development, food quality testing, and advanced biotechnology applications.
Specifications
| Condenser Temperature | Less than or equal to -35°C |
| Layer Temperature Accuracy | Less than or equal to ±1°C |
| Shelf Temperature | -25°C to +80°C |
| Minimum Layer Temperature | Less than or equal to -25°C |
| System Ultimate Vacuum Degree | Less than or equal to 5 Pa |
| Layer Cooling Rate | Less than or equal to 120 min (+20°C to -25°C) |
| Cold Trap Cooling Rate | 20°C to -35°C within 20 min |
| Layer Heating Rate | Less than or equal to 120 min (-25°C to +20°C) |
| Condenser Capacity | Less than or equal to 3 kg |
| Bulk Capacity | 2 kg/batch |
| Liquid Product Capacity | About 2L (thickness 10mm) |
| Vial Capacity Φ 12 mm | 710 vials |
| Vial Capacity Φ 16 mm | 405 vials |
| Vial Capacity Φ 22 mm | 210 vials |
| Layer Spacing | 43 mm |
| Refrigerant | R404 |
| Noise Level | Less than or equal to 62 dB |
| Defrosting Method | Electric heating defrosting |
| Freeze Drying Area | 0.1 m² |
| Layer Dimension (L×H) | 150 mm × 280 mm |
| Power Consumption | 1100 W |
| Power Supply | Single phase 220V |
| Packaging Dimension (L×W×H) | 570 × 680 × 1170 mm |
| Dimension (L×W×H) | 450 × 500 × 825 mm |
| Packaging Weight | 113 kg |
| Weight | 73 kg |
Features
Supports multiple vial sizes
Single-phase power compatibility
Low operational noise output
Uniform temperature layer control
Anti-leak integrated structure
FAQs
1. What makes the Pilot Standard Freeze Dryer suitable for sensitive sample handling?
Pilot Standard Freeze Dryer uses a low-temperature sublimation method that preserves structural and chemical properties during drying. It's ideal for temperature-sensitive organic materials and biological samples. This feature ensures materials retain their core characteristics throughout the process. The drying method reduces stress on delicate compounds. Users in biopharmaceuticals often prefer this for fragile ingredients. The unit minimizes product collapse or shrinkage. Its performance is consistent across small-batch applications. A well-regulated pressure profile also helps stabilize molecular structures during the transition phase. The chamber environment is precisely tuned to support consistent results across batches with varying composition.
2. Can the Pilot Standard Freeze Dryer be used for educational institutions or academic research?
The Pilot Standard Freeze Dryer fits perfectly into academic settings due to its manageable size and ease of operation. Its data recording functionality allows documentation for lab reports and research. The equipment is compact enough to fit in tight lab spaces. Maintenance requirements are minimal. Training students is straightforward due to the clear control interface. Teachers benefit from the system’s visibility of cycle parameters. It serves well in practical demonstrations and research validation. Additionally, its safety features help instructors maintain secure learning environments during hands-on sessions. Laboratory coordinators appreciate its low learning curve when used in multi-user classrooms.
3. How does the Pilot Standard Freeze Dryer handle variations in sample types?
It designed the Pilot Standard Freeze Dryer to accommodate fruits, herbs, extracts, and biological specimens. Each tray supports uniform drying regardless of sample shape or texture. The device supports mixed product runs within a single batch. Its internal layout ensures airflow reaches all layers. This setup minimizes cycle discrepancies. Researchers can optimize cycles with built-in control flexibility. Suitable for low-moisture and high-density items. The chamber’s spacing and programmable settings allow cross-discipline labs to process diverse materials without equipment adjustments. It also prevents contamination crossover between different sample types during concurrent runs.
4. Is the Pilot Standard Freeze Dryer equipped for international power configurations?
Its design supports single-phase 220V, which suits many global power standards. This allows for easy export without needing external converters. It ships units with plug types matching the destination region. Clients can request custom power configurations during procurement. The product manual lists compatible voltage ranges. It simplifies procurement for international buyers. Export-ready design is part of its versatility. The internal circuitry is stress-tested for voltage fluctuations to ensure long-term stability across regions. This makes it a reliable choice for overseas labs with inconsistent power conditions.
5. What are the packaging and transport considerations for the Pilot Standard Freeze Dryer?
freeze dryer is shipped with reinforced protective packaging designed to prevent vibration damage. Custom foam linings and brackets are used for internal stability. The crate size allows for forklift compatibility. All export packaging complies with 15 standards. A packaging list and installation guide are included. This ensures all units pass drop and impact checks. Additional corner buffers and water-resistant wraps are included to protect the unit during unpredictable shipping conditions. Transit indicators are also attached to notify handlers of any tilting or mishandling during logistics.
6. Can the Pilot Standard Freeze Dryer be used in low-noise environments?
It built this product with a compressor system known for reduced vibration and minimal operational sound. This makes it ideal for labs with noise-sensitive instrumentation or working areas. The cooling and vacuum units are enclosed for acoustic insulation. The overall decibel level supports a quiet workspace. Some labs even place it adjacent to workbenches. Unlike industrial systems, it's made for quieter zones. It’s engineered for peace in shared labs. Lab technicians often report uninterrupted workflow even when placed near precision sound monitoring setups. The low-sound profile contributes to a more focused work atmosphere in collaborative research environments.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.