Introduction

A petroleum auto ignition point tester is an instrument used to measure the auto-ignition temperature of the petroleum products and the chemicals, which is the lowest temperature at which the substance ignites spontaneously in the air without an ignition source, and it is used in the petroleum, the chemical, the safety, and the many other industries. The auto-ignition temperature is measured by the heating of the sample in a flask or a vessel in the presence of the air, and the observation of the ignition, following the standard test methods, such as the ASTM standards, and it provides the auto-ignition temperature, which is important for the safety and the classification of the flammable liquids; the petroleum auto ignition point tester consists of a heated flask or a vessel, a temperature control and a measurement system, an air supply, and the observation, and it provides features such as the temperature display and the safety; the petroleum auto ignition point tester is used for the measurement of the auto-ignition temperature of the fuels, the solvents, the lubricants, and the other chemicals, for the safety assessment, for the classification, for the quality control, and for many other applications, and it is an essential instrument for the safety testing. Petroleum auto ignition point testers are used in the petroleum industry, in the chemical industry, in the safety, in the laboratories, and for many other applications. With their auto-ignition measurement, petroleum auto ignition point testers are essential for the safety assessment.

Auto-ignition Point Tester T-S210AIP

Auto-ignition Point Tester T-S210AIP


Auto-ignition Point Tester employs PID control to maintain precise temperature settings within a range of 100 °C to 800 °C. It utilizes advanced data processing chips for efficient and ...

Standards

Complies with the above standards, but is not limited to them.

Features

1. Determines auto-ignition temperature of petroleum products and chemicals by heated flask method.

2. Precision temperature-controlled heating flask with observation system for ignition detection.

3. Suitable for evaluating fire and explosion hazard of flammable liquids and chemicals.

4. Digital temperature control with programmable test sequence for reproducible results.

5. Includes test flask, thermometer and safety enclosure for safe operation.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The petroleum auto ignition point tester is used in petroleum, chemical, safety and research laboratories to determine the auto-ignition temperature of flammable liquids, petroleum products and chemicals. It supports fire hazard classification, chemical process safety assessment, transportation classification and storage safety evaluation. The auto-ignition temperature is the minimum temperature at which a substance spontaneously ignites in air without an external ignition source, which is critical for classifying flammable hazards, designing safe storage and processing conditions, and complying with transportation and workplace safety regulations for hazardous materials.

Q2: What standards does the instrument comply with?

A: The test method follows ASTM E659 for autoignition temperature of liquid chemicals, ISO 871 for plastics autoignition temperature, and relevant GB/T standards for hazardous chemicals. The instrument complies with relevant laboratory electrical and fire safety standards. Test flask dimensions and temperature measurement should follow the standard specification.

Q3: What is the warranty period for the whole machine and key components?

A: The whole tester is covered by a 12-month warranty. The heating system, controller and safety enclosure are covered, while test flasks and thermometers are consumables excluded from warranty. Damage from improper sample handling, overheating or unauthorized repair is excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained personnel familiar with flammable material testing and fire safety procedures. We provide an operation manual and remote guidance. Proper sample introduction, observation of ignition and safety precautions are essential. Testing should be performed in a properly ventilated area with fire safety equipment available.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Temperature calibration against a reference thermometer is recommended every 6-12 months. Flask condition should be inspected before each test and replaced when contaminated or damaged. Full system verification with a reference substance is recommended for accredited laboratories.

Q7: Are supporting consumables universal?

A: Test flasks and thermometers are available from laboratory suppliers, though dimensions should match the standard method. Long-term consumable cost is low, with flask replacement being the main recurring item.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes maximum temperature, flask size and automation level. Additional flasks, thermometers and safety accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the instrument and accessories with an operation manual. Remote commissioning guidance is provided. On-site installation and training are not included for standard orders but can be arranged for safety-critical installations.

Q10: What types of samples are compatible with this equipment?

A: The tester handles flammable liquids and chemicals within the temperature range and flask capacity. Highly volatile samples require careful handling to prevent premature vapor loss. Samples that decompose before ignition may produce misleading results. Users should follow proper safety procedures and verify that the test method is appropriate for the substance being tested. The instrument should not be used with explosive mixtures beyond the designed safety enclosure.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry