Introduction

Vertical Autoclave has a capacity of 100 for handling large sterilization loads. It includes over-temperature auto protection, which automatically shuts down the system. The anti-dry burning system prevents the heater from operating without sufficient water. The system also features an overcurrent power cutoff, disconnecting the power supply. Our vertical autoclave has an overpressure relief valve that maintains optimal chamber pressure.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Vertical Autoclave is a sterilization device that uses high-pressure saturated steam to disinfect laboratory and medical equipment. It is widely used in microbiology labs, hospitals, and research centers for safe and efficient sterilization of media, glassware, and instruments. 

Specifications

Capacity 100 L
Chamber Volume Ø450 × 650 mm
Working Sterilization Temperature 134℃
Sterilization Temperature 116℃ to 134℃
Working Sterilization Pressure 0.22 MPa
Design Pressure 0.25 MPa
Design Temperature 139℃
Working Pressure 0.22 MPa
Sterilization Time Range 4 to 120 min
Drying Time Range 0 to 240 min
Bucket Dimension Ø430 × 550 mm
Basket Dimension Ø410 × 300 × 2 mm
Power Consumption 4.5 kW, AC 220V, 50Hz
Outer Dimension (L × W × H) 555 × 555 × 1250 mm
Packing Dimension (L × W × H) 690 × 650 × 1410 mm

Features

Automatic Pressure Adjustment

Temperature Uniformity Control

Sturdy Locking Mechanism

Long-Lasting Heating Element

Customizable Sterilization Programs

FAQs

1. Are vertical autoclaves energy-efficient and eco-friendly?

It designs its vertical autoclaves with energy conservation in mind. Many models feature automatic shut-off systems, insulated chambers, and efficient heating elements that reduce energy consumption without compromising performance. Some models also recycle steam or minimize water usage during the sterilization process, making them more environmentally friendly. This not only helps labs reduce their operational costs but also aligns with modern sustainability goals in scientific research and healthcare.

2. How portable are vertical autoclaves for labs with space constraints?

It addresses the need for mobility and space-efficiency by offering compact vertical autoclaves equipped with sturdy caster wheels and ergonomic handles for easy maneuvering. These models are ideal for laboratories where floor space is limited, or where the autoclave must be moved between workstations or departments. Despite their smaller size, these units still maintain high sterilization capacity and include essential features such as programmable cycles, safety locks, and steam regulation. This portability makes them especially useful for clinical labs, academic institutions, diagnostic centers, and mobile sterilization units.

3. What kind of after-sales support does offer for vertical autoclaves?

It is committed to providing not just high-quality equipment but also reliable post-purchase support. Upon purchase, clients receive detailed user manuals, installation instructions, and online training videos to help operators get started confidently. For long-term care, It provides technical assistance through email, phone, or remote diagnostics, along with preventive maintenance guides. When needed, replacement parts such as gaskets, sensors, and heating elements can be shipped promptly, and on-site servicing can be arranged through certified technicians. This full-spectrum support ensures that the autoclave remains fully functional, safe, and compliant over its entire operational life.

4. Can vertical autoclaves be integrated into cleanroom environments?

It offers vertical autoclaves that are well-suited for cleanroom integration due to their sterile-grade stainless steel construction (SS316) and minimal external joints or crevices, which reduces the risk of contamination. These models are easy to sanitize and often feature filters and gasket-sealed lids to maintain an aseptic environment. The seamless design, along with low-noise and vibration operation, makes them ideal for pharmaceutical cleanrooms, bioprocessing units, and -certified labs, where sterility is non-negotiable.

5. Are vertical autoclaves suitable for -2 and -3 laboratories?

It vertical autoclaves are engineered to meet the stringent sterilization demands of -2 and -3 laboratories. These units ensure complete microbial decontamination of infectious materials through validated sterilization cycles. They come with safety interlocks, bioseal-compatible configurations, and optional double-door/pass-through models for bio-containment environments. This allows safe sterilization of contaminated tools, , and waste before they exit high-containment zones, helping prevent exposure and cross-contamination.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.