Introduction
Inverted Biological Microscope provides a magnification range from 40x to 400x for precise observation of cultured cells. It includes a wide field PL10X/22mm eyepiece and long working distance infinity plan achromatic objectives. The quintuple nosepiece allows quick switching between 4x, 10x, 20x, and 40x objectives. The clear illumination. This microscope suits research, medical labs, and educational environments focused on cell culture studies.
This microscope is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Inverted Biological Microscope provides excellent optics for observing living cells, designed for research and medical use with an ergonomic, user-friendly setup.
Specifications
| Optical System | Infinite Optical System |
| Viewing Head | 45° Trinocular Tube, Interpupillary Distance: 48-76mm, Splitting Ratio: 100:0 or 80:20, Eyepiece Tube Diameter: 30mm |
| Eyepiece | Wide Field Plan Eyepiece PL10X/22mm, Adjustable Diopter |
| Objectives | 4X/NA=0.11, WD=12.1mm; 10X/NA=0.25, WD=10.3mm; 20X/NA=0.45, WD=5.8mm; 40X/NA=0.65, WD=5.1mm |
| Nosepiece | Quintuple Nosepiece |
| Condenser | Long Working Distance Condenser, N.A. 0.3, WD: 72mm (with condenser), 195mm (without condenser) |
| Centering Telescope | Φ30mm Centering Telescope |
| Phase Annulus | 10X, 20X/40X Phase Annulus Plates |
| Stage | Size: 210mm(X) × 241mm(Y), Round Size: Φ110mm, Moving Range: 128mm(X) × 80mm(Y), Mechanical Stage for 96 Holes Plate, X-Y Coaxial Control Φ54mm culture dish holder |
| Focusing | Coaxial Coarse and Fine Adjustment, Fine Division: 0.002mm, Moving Range: 10mm |
| Illumination | 12V/30W Halogen Lamp, Input Voltage: 100V |
| Filter | Blue Filter (Φ34mm), Green Filter (Φ34mm) |
| C-mount | 0.5X C-mount Adapter, Adjustable Focus |
| Dimension | 520 × 470 × 490 mm |
| Net Weight | 14 kg |
| Gross Weight | 18 kg |
Features
Adjustable light distribution ratios
Long working distance condenser
Dual-handed mechanical stage control
High-intensity fluorescence unit
Compatible with high-culture dishes
Wide stage to hold samples
Large diameter quintuple nosepiece
FAQs
1. What are the key factors to consider when selecting this microscope for laboratory use?
When selecting this microscope, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this microscope be calibrated to ensure accurate results?
It is recommended to calibrate this microscope at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this microscope?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this microscope be used with different types of samples, and are there any compatibility considerations?
Yes, this microscope can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the microscope malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.