Introduction

Comparison Microscope offers a magnification range from 2x to 240x, ensuring precise and detailed forensic analysis. It is equipped with advanced a magnification correction system that includes correcting lenses for accuracy. The working stage supports 360° rotation and multi-angle adjustments for thorough examination. Its light sources, such as UV, , and halogen with adjustable brightness, provide versatile illumination. Our microscope is designed to meet the advanced requirements of forensic investigations with efficiency.

This microscope is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Comparison microscope is commonly used in forensic laboratories, police investigation units and law enforcement agencies for ballistic analysis and evidence comparison.

Specifications

Magnification 2x to 240x
Head 0 to 45° tiltable binocular head, interpupillary distance: 48 to 75 mm, Dioptre: +/-5 adjustable
Eyepiece WF10x /22 mm, high eyepoint
WF20x /12mm, high eyepoint
Nosepiece 6 holes click stop nosepiece
Objective infinity plan achromatic objective 0.5x, 1x, 1.5x, 2x, 4x,6x
Auxiliary Lens 0.4x, 2.0x
Working Distance 101 mm
View Field Diameter 2.3 to 62 mm
Working Stage Square manual working stage 90 × 90 mm, moving range 54 × 54 × 54 mm
Round tiltable working stage, diameter: 90 mm, 0 to 45° inclined, 360° rotatable
Joint left/right moving range 54 mm, joint up/down range 60 mm
Light Source 12V 50W fan cooling strong halogen light, brightness adjustable, 2pcs
5W cold light, high brightness, brightness adjustable, 2pcs
Coaxial light lens, to observe in deep hole, or smooth object surface, 2pcs
Polarizing light lens, to eliminate flare lights and dazzling lights, 2pcs
Transmit bottom light (built-in working stage)
Ultraviolet light lens, 2pcs
Filters: red, blue, yellow, green, 2pcs each colour
Adapter 0.5x adapter for digital camera,1pc
Front view photo adapter 2.5x for digital camera
Camera built-in 3.0 m high resolution colour camera, 2.0 Output, 2048 × 1536 pixels, Pixel size: 3.2 × 3.2 µm
Software Professional forensic image analysis software
Motorized/Manual view field changeover full /split /overlapping image
Motorized/Manual control working stage x/y/z 3d movement
Motorized/Manual control round working stage rotation +/- direction
Motorized/Manual control to change objective magnification
Power 80 to 240 V wide range voltage
No. of Bullet Holder 2 sets
Dimension 400 × 600 × 720 mm

Features

Separation line adjust system

Include professional forensic image analysis software

Multiple illumination modes

Motorized control for magnification

Bullet holder set to hold & view all kinds of cartridge and bullet

FAQs

1. What are the key factors to consider when selecting this microscope for laboratory use?

When selecting this microscope, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this microscope be calibrated to ensure accurate results?

It is recommended to calibrate this microscope at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this microscope?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this microscope be used with different types of samples, and are there any compatibility considerations?

Yes, this microscope can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the microscope malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.