Introduction

Spin Vacuum Tissue Processor is designed for efficient tissue processing, featuring a 2.3L double basket reagent cup to accommodate larger volumes. It supports 12 customizable tissue processing steps, offering flexibility for different tissue types and research needs. The duration for each reagent cup is adjustable from 0 to 10 hours, providing precise control over the tissue preparation process. The rotating sample basket ensures thorough reagent mixing every five minutes, enhancing reaction efficiency. This tissue processor is ideal for laboratories focused on high-performance tissue processing in research and diagnostics. This tissue processor is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Spin Vacuum Tissue Processor is ideal for tissue dehydration, paraffin embedding, and sample preparation in histopathology labs, research facilities, and diagnostic

Specifications

Reagent Cup Capacity 2.3L (Double Basket)
Number of Tissue Baskets 2
Number of Reagent Cups 9
Number of Paraffin Cups 3
Program Duration in Each Cup 0 to10 hours (10 programs)
Tissue Processing Steps 12 steps
Basket Stirring Frequency ≥10 times/hour; 30 sec for each time
Minimum Time Interval Setting 1 min
Program Maximal Turn-on Delay 1 month
Voltage & Frequency AC 220V ±10%, 50Hz
Power 1000W
Basket Size 95mm × 80mm
Dimension 670(D) × 540(H) mm (680mm at highest point)
Net Weight 60kg

Features

Sample basket with automatic rotation

Transparent glass reagent cylinder with handles

Internal and external safety limiters

Obstacle detection sensor for safety

10 built-in programming options

Timed pause for reagent drip off

Delayed start function up to 30 days

FAQs

1. What are the key factors to consider when selecting this tissue processor for laboratory use?

When selecting this tissue processor, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this tissue processor be calibrated to ensure accurate results?

It is recommended to calibrate this tissue processor at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this tissue processor?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this tissue processor be used with different types of samples, and are there any compatibility considerations?

Yes, this tissue processor can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the tissue processor malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.