Introduction
Potentiostat supports CV scan rate from 0.001mV to 10,000V/s for flexible and correct analysis. It ensures high-resolution measurement with advanced signal processing capabilities. Integrates multi-channel functionality for simultaneous multiple electrode evaluation. Features over-voltage protection ensuring safe operation during process. Compatible with leading analysis software for enhanced data interpretation. This potentiostat is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Potentiostat supports advanced research in energy materials like Li-ion batteries, solar cells, and super capacitors, enabling studies in electrosynthesis, corrosion protection, electrodeposition, and electro catalysis for , , , and CO₂RR.Specifications
| Electrode System | 2-, 3-, or 4-electrode system |
| Potential Control Range | ±10V |
| Potential Control Accuracy | 0.1% × full range ± 1mV |
| Potential Resolution | 10μV (>100Hz), 3μV (<10Hz) |
| Current Control Range | ±2A |
| Current Control Accuracy | 0.1% × full range |
| Current Sensitivity | 1pA |
| Rise Time | <1μs (<10mA), <10μs (<2A) |
| Reference Electrode Input Impedance | 10¹²Ω||20pF |
| Current Range | 2nA to 2A, 10 ranges |
| Compliance Voltage | ±21V |
| Maximum Current Output | 2A |
| CV and Scan Rate | 0.001mV to 10,000V/s |
| CA and CC Pulse Width | 0.0001 to 65,000s |
| Current Increment During Scan | 1mA at 1A/ms |
| Potential Increment During Scan | 0.076mV at 1V/ms |
| Frequency | 0.001 to 100kHz |
| and Pulse Width | 0.0001 to 1000s |
| AD Data Acquisition | 16-bit at 1 MHz, 20-bit at 1 kHz |
| DA Resolution | 16-bit, setup time: 1μs |
| Minimum Potential Increment (CV) | 0.075mV |
| Frequency | 10μHz to 1MHz |
| Low-pass Filters | Covering 8-decade |
| Operating System | Windows 10/11 |
| Interface | 2.0 |
| Signal Generator Frequency Range | 10μHz to 1MHz |
| AC Amplitude | 1mV to 2500mV |
| DC Bias | -10 to +10V |
| Output Impedance | 50Ω |
| Waveform Types | Sine, triangular, and square wave |
| Wave Distortion | <1% |
| Scanning Modes | Logarithmic/linear, increase/decrease |
| Signal Analyzer Integral Time | Minimum: 10ms or cycle time; Maximum: 10⁶ cycles or 10⁵s |
| Measurement Delay | 0 to 10⁵s |
| Potential Automatic Compensation Range | -10V to +10V |
| Current Compensation Range | -1A to +1A |
| Bandwidth | 8-decade frequency range, automatic/manual setting |
| Dimensions | 365mm×305mm×160mm |
| Weight | 6.5kg |
Features
High-resolution voltage control
Multi-electrode system support
Fast response rise time
Advanced noise-reduction technology
Programmable experimental workflows available
FAQs
1. What are the key factors to consider when selecting this potentiostat for laboratory use?
When selecting this potentiostat, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this potentiostat be calibrated to ensure accurate results?
It is recommended to calibrate this potentiostat at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this potentiostat?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this potentiostat be used with different types of samples, and are there any compatibility considerations?
Yes, this potentiostat can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the potentiostat malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.