Introduction

Rockwell Hardness Tester offers a preliminary test force of 29.4 N and total test forces of 147.1, 294.2, and 441.3 N, enabling versatile testing across different materials. Its digital display ensures precise hardness readings with a resolution of 0.1 HR, providing high accuracy. These features make it a dependable choice for consistent hardness testing in manufacturing, material analysis, and various other applications. This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Rockwell Hardness Tester is ideal for quality control in metal manufacturing and mechanical engineering. It is also used in material testing labs for determining the hardness of a wide range of metals and alloys.

Specifications

Hardness Testing Range HR15N:70-94, HR30N:42-86 HR45N:20-77, HR15TW:67-93, HR30TW:29-82, HR45TW:10-72
Rockwell Scale 15N, 15T, 15W, 15X, 15Y, 30N, 30T, 30W, 30X, 30Y, 45N, 45T, 45W, 45X, 45Y
Initial Load of Rockwell 3kgf(29.42N)
Total Load of Rockwell 15Kgf(147.1N) 30Kgf(294.2N) 45Kgf(441.3N)
Dwell Time 0-99s
Resolution of Hardness Value 0.1HR
Load Value Error < 1%
Hardness Reading Display
Conversion Scale Rockwell, Surface Rockwell, Brinell and Vickers
Standards 6508, 6508, E18, GB/T230
Max Height of Specimen 300mm for common sample table, 200mm with X mobile station, 100mm for X/y mobile station
Distance from the Centre to the outer wall of the Indenter 200mm
X/y motor table stroke 100mm (optional 200 mm)
Accuracy of X/y motor table 0.005mm
Power Supply AC 220 V, 50 to 60 Hz, 600W
Overall Dimensions 560 × 280 × 850mm
Weight 80Kg

Features

Supports , , scales

Ensures precise measurements

Durable industrial frame

Quick test cycles

, RS232, Ethernet connectivity

Intuitive touchscreen

Auto calibration and diagnostics

Overload protection and emergency stop

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.