Introduction

Flash Point Tester measures ignition of liquid at temperature upto 370℃. It features user-friendly 7" color touch screen interface for easy operation. Equipped with automatic test completion and real-time progress display functionality. Includes interchangeable gas and electric ignition for flexible usage. Designed for high safety standards and efficient cooling system performance.

This petroleum testing is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Flash Point Tester is essential in laboratories, oil refineries and chemical manufacturing. It ensures compliance with safety regulations and effective risk management in hazardous materials handling.

Specifications

Measuring Range 40 to 370℃ (104 to 698℉)
Resolution 0.1℃
Heater Rate Procedure A: 5℃/min to 6℃/min
Procedure B: 1.0℃/min to 1.5℃/min
Procedure C: 2.5℃/min to 3.5℃/min
Stirring Speed Procedure A: 90r/min to 120r/min
Procedure B: 250r/min ± 10r/min
Procedure C: 90r/min to 120r/min
Sample Preheating Side: Ambient to 95℃; Center: Ambient to 95℃
Safety Features Automatically shuts down, alarm, and cooling, in case:
Flash Point Mode: + 20℃ is reached
400℃ is reached
Cooling Air cooling
Gas Supply LP gas, butane gas, pipeline gas or natural gas (pressure < 10kPa)
Ignition Source Gas ignition or electric ignition, interchangeable
Ignition Power ≤50W
Flash Point Detection Thermocouple
Temperature Sensor PT100 probe
User interface 7
Languages Chinese, English, Russian
Barometric correction Flash point is corrected to barometric pressure
Data Storage No less than 5000 results
I/O Port RS232,
Standards D93, 2719, IP 34, GB/T 261
Data Export or Printer
Machine Power 800W
Heater Power 500W
Operating Conditions 5℃ to 35℃
20 to 90%RH at 35℃ Non-condensing
No air flow
Power Supply AC 220V±10 50/60Hz
Dimensions (W×D×H) 265mm× 525mm× 365mm
Weight 20 Kg
Gross Weight 35 Kg

Features

Five pre-programmed test methods

Interchangeable ignition options

Built-in gas control valve

iSKvator software automation

Optional printer export available

FAQs

1. What are the key factors to consider when selecting this petroleum testing for laboratory use?

When selecting this petroleum testing, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this petroleum testing be calibrated to ensure accurate results?

It is recommended to calibrate this petroleum testing at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this petroleum testing?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this petroleum testing be used with different types of samples, and are there any compatibility considerations?

Yes, this petroleum testing can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the petroleum testing malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.