Introduction

Real Time has a capacity of 48×0.2ml, making it compatible with both 8-tube strips and individual single-tubes. It can accommodate volumes from 20µl to 120µl, allowing flexibility for various sample sizes. Our Real-Time features four-color fluorescence channels, allowing versatile testing options. This portable can start experiments in 30 seconds, eliminating preheating and speeding up the testing process. This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Real-time allows for both quantitative and qualitative analysis of and from human samples, including the detection of pathogens. It is widely used in basic research, drug development, and pathogen screening.

Specifications

Sample Capacity 48 × 0.2 ml
Volume Range 20 µl to 120 µl
Applicable Consumables 0.2ml single tube, 8 × 0.2ml tube strip
Temperature Range 4°C to 100°C
Working Temperature 15℃ to 30℃
Storage Temperature -20℃ to 55℃
Ambient Relative Humidity ≤85%
Heating/Cooling Method Semiconductor heating method, independent and intelligent temp. control over 4 zones
Ramp Rate Heating: 4 ℃/s, Cooling: 4℃/s
Temperature Accuracy ±0.2℃
Temperature Uniformity ±0.5℃
Temperature Control Technology 4-zone independent temperature control combined with thermal compensation technology
Gradient Temperature Function Yes
Gradient Temperature Columns 8
Gradient Temperature Range 1℃ to 32℃
Gradient Temperature Zones 4
Gradient Temperature Set Range 30℃ to 100℃ (Room temperature is lower than 28°C)
Excitation Source
Detection Device PD
Light Propagation Medium Dual-48 high-temperature resistant optical fibers for Space
Detection Channels 4
Excitation Range 1st Channel: 470nm±10nm
2nd Channel: 525nm±10nm
3rd Channel: 570nm±10nm
4th Channel: 620nm±10nm
Detection Range 1st Channel: 520nm±10nm
2nd Channel: 570nm±10nm
3rd Channel: 620nm±10nm
4th Channel: 670nm±10nm
Dye Compatibility / Green/Eva Green/LC Green/Fluorescein
///Cy3/
/Cy5.5/Texas Red
Cy5
Detection Sensitivity ≥1 copy
Confidence Coefficient 0.999
Sensitivity Allowed 1.5-fold in single reaction
Sample Detection Repeatability CV≤3%
Linear Range 1 to 10^9 copy
Sample Linearity ≥ 0.98
Software Function Quantitative/Absolute Quantification
Standard Melting Curve Analysis
Endpoint Allelic Genotyping
Melting Curve Analysis for Genotyping
Relative Quantification
Isothermal Amplification
Software Output //
Safety Compliances CE/ISO9001/ISO13485
Power Supply 220 V, 50 Hz, 865VA
Dimension 466 × 310 × 273 mm
Weight 17.5 Kg

Features

Intuitive software

Compact

Intelligent four-zone temperature control

Multiple connections to one computer

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.