Introduction
An anti-dry thermostatic water bath is a water bath with the anti-dry protection, used for the heating and the incubation of the samples at the controlled temperatures, and it is used in the chemistry, the biology, the clinical, and the many other laboratories. The anti-dry thermostatic water bath consists of an insulated bath, the heating elements, a temperature control system, a temperature sensor, and the controls, and it heats the water to the controlled temperature, providing the uniform heating of the vessels and the samples placed in the bath, with the anti-dry protection shutting off the heating when the water level is low, preventing the damage; the anti-dry thermostatic water bath is used for the incubation of the samples, for the heating of the reagents and the media, for the thawing, for the temperature control of the reactions, for the calibration, and for many other applications, and it is available in various sizes and temperature ranges; the anti-dry thermostatic water bath provides a safe and a reliable heating, and it is an essential instrument for the laboratory. Anti-dry thermostatic water baths are used in the chemistry laboratories, in the biology laboratories, in the clinical laboratories, in the research, and for many other applications. With their anti-dry protection, anti-dry thermostatic water baths are essential for the safe incubation.
Anti-Dry Thermostatic Water Bath T-S2WB-S2103
Anti-Dry Thermostatic Water Bath T-S2WB-S2104
Anti-Dry Thermostatic Water Bath T-S2WB-S2101
Anti-Dry Thermostatic Water Bath T-S2WB-S2102
Anti-Dry Thermostatic Water Bath T-S2WB-S2100
Standards
ASTM E2488-09(2014)-Standard Guide for the Preparation and Evaluation of Liquid Baths Used for Temperature Calibration by Comparison
Complies with the above standards, but is not limited to them.
Features
1. Anti-dry thermostatic water bath with automatic shut-off for safe operation.
2. Precision temperature control with uniform heating for laboratory incubation and heating.
3. Anti-dry protection prevents damage when water level is insufficient.
4. Suitable for chemistry, biology, clinical and educational laboratory applications.
5. Includes bath tank, heater, controller and operation manual.
FAQ
Q1: What testing scenarios is this bath mainly applied to?
A: The anti-dry thermostatic water bath is used in chemistry, biology, clinical, pharmaceutical and educational laboratories for temperature-controlled heating and incubation of samples. It supports reagent warming, sample incubation, enzyme assays, media preparation, thawing of biological samples, general laboratory heating and temperature-sensitive experiments. The anti-dry protection automatically shuts off the heater when water level drops below a safe threshold, preventing heating element damage and fire hazards associated with dry operation. It is essential for laboratories requiring reliable, safe water bath operation for routine applications where unattended operation or varying water levels could lead to equipment damage or safety risks, providing peace of mind for users running incubation or heating procedures over extended periods.
Q2: What standards does the bath comply with?
A: The water bath is designed with reference to IEC 61010 laboratory electrical safety standards and relevant GB/T standards for laboratory heating equipment. Temperature accuracy should be verified with a calibrated reference for critical applications. The anti-dry protection follows applicable safety standards for laboratory heating equipment.
Q3: What is the warranty period for the whole machine and key components?
A: The whole bath is covered by a 12-month warranty. The heating element, controller and anti-dry sensor are covered, while the power cord is an accessory. Damage from operating without water despite the protection, corrosive water damage or unauthorized repair is excluded.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is simple: fill with water, set temperature, allow stabilization and place samples inside. No professional training is required, but users should follow safe heating practices and maintain proper water level. We provide an operation manual and remote guidance.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Temperature calibration against a reference thermometer is recommended every 6-12 months. Anti-dry sensor function should be tested periodically. Water level and bath cleanliness should be maintained regularly. No formal metrological calibration is typically required beyond temperature verification.
Q7: Are supporting consumables universal? What about the long-term procurement cost?
A: There are no recurring consumables. The heating element is durable. Long-term ownership cost is very low for a benchtop water bath.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes bath capacity, temperature range, controller type and rack configuration. Additional test tube racks, lids and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: No installation is required beyond water filling and power connection. The package includes the bath and instruction manual. On-site service is not included for this type of benchtop instrument.
Q10: What types of samples are compatible with this equipment?
A: The bath heats compatible vessels and aqueous solutions within the temperature range. Highly corrosive solutions should not be placed directly in the bath water. Flammable solvents require appropriate fume hood protection. Users should maintain proper water level, use distilled or deionized water to minimize scale buildup, and ensure the anti-dry protection is functional before unattended operation. Samples should be properly sealed to prevent water contamination and evaporation.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.