Ultrapure Water System can produce 20 liters of purified water per hour at a flow rate of 1.5 to 2L/min. Equipped with a color touchscreen display for real-time monitoring and data visualization. It utilizes engineering plastic with a powder-coated surface to improve water quality and increase volume. Our water system requires an inlet water pressure of 0.15 to 0.5 megapascals for optimal operation. Designed with a 10μm stainless steel filter mesh and silicone soft scraping for consistent cleaning.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Ultrapure Water System is ideal for cleaning glassware, physical and chemical testing, biochemical analysis, blood examination, microanalysis, , IC, GC, and other analytical experiments
Specifications
| Water Output Rate | 20L/Hr |
| Water Flow Rate | 1.5 to 2L/min (with pressure barrel) |
| Water Temperature | 5 to 40°C |
| Inlet Water Pressure | 0.15 to 0.5mpa |
| Concentration | < 400 ppm |
| Water Requirements | Urban Tap Water, RO Water, UP Water ( type I grade water) |
| RO Water Ion Rejection Rate | 97 to 99% (when using a new RO membrane) |
| RO Water Organic Matter Rejection Rate | > 99% when MW >200 Dalton |
| RO Water Particle and Bacterial Rejection | > 99% |
| UP Water Resistivity | 18.25 MΩ.CM at 25°C |
| UP Water Total Organic Carbon (Toc) | <10 ppb |
| UP Water Heavy Metal Ion | <0.01 ppb |
| Bacteria | <0.01 cfu/ml (With Terminal Filter) |
| Particulate Matter (>0.1 Microns) | <1/ml |
| Display | Color touchscreen |
| Materials | Engineering Plastic Case, Powder Coating Technology |
| Interface | |
| Power Consumption | 120W |
| Power Supply | 110 to 240V, 50/60Hz |
| Dimensions | 550 × 630 × 680 mm |
| Weight | 42 Kg |
Features
High adsorption efficiency and long lifespan
Includes pen for measuring dissolved solids
Inbuilt feed water pressure test gauge
Automatic reminder for filter replacement
Integrates water quality sensors and switch signals
FAQs
1. What are the key factors to consider when selecting this water purification system for laboratory use?
When selecting this water purification system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this water purification system be calibrated to ensure accurate results?
It is recommended to calibrate this water purification system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this water purification system?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this water purification system be used with different types of samples, and are there any compatibility considerations?
Yes, this water purification system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the water purification system malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.