Introduction

A Bacti-Cinerator sterilizer, also known as a microincinerator or bench-top incinerator, is a laboratory instrument used to rapidly sterilize inoculating loops and needles by heating them in a high-temperature chamber or flame, and it is used in microbiology laboratories for sterilizing inoculation tools between uses. The sterilizer consists of a heating element in a ceramic chamber or tube that reaches a high temperature, typically 800-900 degrees Celsius, and a fan that draws air through the chamber; in operation, the inoculating loop or needle is inserted into the heated chamber, and the high temperature incinerates the microorganisms on the loop within a few seconds, providing rapid and effective sterilization, and the sterilizer is safer and more convenient than an open flame, since it contains the heat and reduces the risk of aerosols and contamination; the sterilizer is designed to operate continuously, with the heating chamber at the high temperature, ready for the insertion of the loop, and it is suitable for sterilizing metal inoculation loops and needles, which cool quickly after removal. Bacti-Cinerator sterilizers are used in microbiology laboratories for sterilizing inoculating loops and needles between cultures and streaks, in clinical laboratories, in educational laboratories, in food and pharmaceutical microbiology, and in many other applications, and they are available in various designs, including benchtop models with a ceramic chamber and infrared heaters, with features such as quick heating, continuous operation, and a compact design. With their rapid and safe sterilization, Bacti-Cinerator sterilizers are essential instruments for microbiology work.

Bacti-T20inerator Sterilizer LBCS-T2013

Bacti-T20inerator Sterilizer LBCS-T2013



Bacti-Cinerator Sterilizer has a compact design and is capable of reaching a maximum temperature of 825°C. It offers a safe and convenient sterilization method that completely replaces ...
Bacti-T20inerator Sterilizer LBCS-T2012

Bacti-T20inerator Sterilizer LBCS-T2012



Bacti-Cinerator Sterilizer features a compact design and is capable of reaching a maximum temperature of 825℃. It is an advanced alcohol-free sterilizing solution, perfect for inoculati...
Bacti-T20inerator Sterilizer LBCS-T2010

Bacti-T20inerator Sterilizer LBCS-T2010



Bacti-Cinerator Sterilizer is a benchtop design that offers infrared thermal sterilization with a temperature of 825℃+50℃. It delivers faster sterilization, making it a highly effectiv...
Bacti-Cinerator Sterilizer LBCS-T2011

Bacti-Cinerator Sterilizer LBCS-T2011



Bacti-Cinerator Sterilizer features a compact design that employs infrared heat sterilization with 825℃+50℃. It produces no smoke or environmental pollutants, ensuring a cleaner and sa...
Bacti-T20inerator Sterilizer LBCS-T2013

Bacti-T20inerator Sterilizer LBCS-T2013



Bacti-Cinerator Sterilizer provides infrared thermal sterilization and a center high temperature of 825℃ ± 50℃. It provides rapid sterilization in 5 to 7 seconds. The sterilizer is su...
Bacti-T20inerator Sterilizer LBCS-T2012

Bacti-T20inerator Sterilizer LBCS-T2012



Bacti-Cinerator Sterilizer can reach a center high temperature of 825℃ ± 50℃ within approximately 10 minutes. It features a special porcelain core that does not crack in the alternati...
Bacti-T20inerator Loop Sterilizer LBCS-T2011

Bacti-T20inerator Loop Sterilizer LBCS-T2011



Bacti-cinerator achieves full sterilization of inoculating loops and needles in only 5 to 7 seconds. It can accommodate sterilization goods with a maximum outer diameter of φ35mm. The s...
Bacti-T20inerator Sterilizer LBCS-T2010

Bacti-T20inerator Sterilizer LBCS-T2010



Bacti-Cinerator Sterilizer is an easy-to-use benchtop sterilizing unit that use IR heat for organic material incineration. Sterilization takes 5 to 7 seconds at an optimum sterilizing te...

Standards

IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Complies with the above standards, but is not limited to them.

Features

1. Bacti-cinerator sterilizer for incineration sterilization of inoculation loops and needles.

2. Electric infrared heating for rapid, flameless sterilization of microbiology tools.

3. Suitable for microbiology laboratories, clinical labs, food testing, pharmaceutical and research.

4. Includes heating element, ceramic tube, controller, housing and operation manual.

5. Supports rapid, flameless sterilization of inoculation loops in microbiology.

FAQ

Q1: What testing scenarios is this sterilizer mainly applied to?

A: The bacti-cinerator sterilizer is used in microbiology laboratories, clinical microbiology, food testing laboratories, pharmaceutical QC, biotechnology, environmental testing and research to sterilize inoculation loops, needles and small microbiology tools by incineration using electric infrared heating (flameless) for rapid, convenient sterilization between microbiological procedures. It supports microbiology laboratory inoculation loop sterilization (between streaks, between samples), clinical microbiology culture processing, food microbiology testing, pharmaceutical QC microbiology, environmental microbiology testing, biotechnology culture work, and general microbiology laboratory use. The bacti-cinerator provides rapid (5-10 seconds), flameless sterilization using infrared heating, eliminating the need for open Bunsen burner flames and associated safety hazards (fire, gas), making it suitable for use in biosafety cabinets, anaerobic chambers and environments where open flames are prohibited.

Q2: What standards does the sterilizer comply with?

A: The bacti-cinerator sterilizer follows relevant ISO, ASTM and GB/T standards for laboratory sterilization equipment, including applicable microbiology laboratory standards and IEC 61010 laboratory electrical safety standards. The hardware complies with applicable safety standards for heated surfaces. Sterilization efficacy should be verified per applicable standards (the infrared heating achieves >800 degrees C, sufficient for incineration of microorganisms). Users should verify compliance with specific facility requirements, especially for use in biosafety cabinets (verify compatibility with BSC airflow and certification).

Q3: What is the warranty period for the whole sterilizer and key components?

A: The whole bacti-cinerator sterilizer is covered by a 12-month warranty. The heating element, ceramic tube, controller and housing are covered, while ceramic tubes and fuses are consumables or accessories. Damage from improper use, overheating or unauthorized repair is excluded. Extended warranty may be available. Heating element lifespan depends on usage (typically 1-3 years).

Q4: Is this device difficult to operate? Is professional training required?

A: Operation is simple: turn on, allow preheating (5-10 minutes), insert inoculation loop into ceramic tube for 5-10 seconds, remove, cool briefly, use. No professional training is required for basic use, but users should follow proper preheating, insertion technique, hot surface safety and aseptic technique. We provide an operation manual and remote guidance. The loop should be inserted into the center of the ceramic tube for maximum heating.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Temperature verification (infrared thermometer or thermocouple) recommended every 6-12 months for critical applications. Heating element condition checked. Ceramic tube inspection (cracks, contamination). Routine cleaning. Full sterilizer performance verification annually. Controller accuracy verified periodically.

Q7: Are supporting consumables universal?

A: Ceramic tubes, inoculation loops (if purchased separately), cleaning supplies and fuses are available from microbiology suppliers, though tube size should match the sterilizer. Long-term consumable cost is very low.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes tube size (for different loop sizes), temperature range, control type, mounting (bench, clamp for BSC), angle and accessories. Additional ceramic tubes, loops and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: No installation is required. The package includes the bacti-cinerator sterilizer and instruction manual. On-site training is available at additional cost for laboratory setup.

Q10: What types of tools are compatible with this equipment?

A: The bacti-cinerator sterilizer sterilizes inoculation loops (nichrome, platinum), inoculation needles, small spreaders and other small metal microbiology tools within the tool size, ceramic tube opening and temperature tolerance specification. Only metal tools should be inserted (plastic or wooden handles will burn/melt). Very large tools may not fit in the ceramic tube. Users should use only metal inoculation loops/needles (nichrome or platinum wire), preheat the sterilizer for 5-10 minutes before use (reach operating temperature >800 degrees C), insert the loop portion into the center of the ceramic tube (not the handle), hold for 5-10 seconds (sufficient for incineration), remove and allow to cool briefly (5-10 seconds) before touching culture (hot loop can kill organisms), avoid touching the hot ceramic tube or heating element (severe burn hazard), use in well-ventilated area or biosafety cabinet (incineration produces small amounts of aerosol - use in BSC for pathogenic organisms), clean the ceramic tube regularly (incineration residue can accumulate), replace ceramic tube when cracked or heavily contaminated, and for biosafety cabinet use, verify the sterilizer is compatible (does not disrupt BSC airflow, does not exceed BSC heat load, some BSCs prohibit heat sources - check with BSC manufacturer). The sterilizer should be placed on a heat-resistant, stable surface. The exterior can become hot during use. The sterilizer should not be left unattended while on. For anaerobic chamber use, verify the sterilizer is rated for use inside anaerobic chambers (some models are specifically designed for this). Waste (incineration residue) should be cleaned from the ceramic tube regularly. The sterilizer should be turned off when not in use (saves energy, extends heating element life). For clinical microbiology, follow proper aseptic technique and biosafety procedures per facility policy. The bacti-cinerator is a safer alternative to Bunsen burners (no open flame, no gas), but still requires proper hot surface safety. The heating element should be replaced when output degrades (takes longer to reach temperature, or does not achieve sterilization temperature).

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.