Introduction
Kinematic Viscometer works in a temperature range of -60℃ to 140℃ with an accuracy of 0.05 ℃. Features a 5.6-inch high-definition color touch screen for a clear interface and easy operation. Capable of testing four samples simultaneously and independently. It utilizes a temperature control technology for high-precision results. Equipped with an imported PT100 temperature sensor for high accuracy. Our viscometer allows the selection of experiment repetitions, adjustable from 1 to 9 times per sample.
This petroleum testing is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our kinematic Viscometer is suitable for measuring the kinematic viscosity of liquid petroleum products. It can be used in various applications, including fuel, lubricating oil, heavy fuel, additives, service oil, and chemicals.
Specifications
| Temperature Range | -60℃ to 140℃ |
| Temperature Accuracy | 0.05 ℃ |
| Measurement | Kinematic Viscosity, Dynamic Viscosity, Density, Viscosity Index |
| Viscosity Range | 0.2 to 30,000 mm²/s |
| Density Range | 0 to 3 g/cm³ |
| Constant Temperature Timing | 0 to 100 minutes |
| Timing Range | 0 to 999.99 seconds |
| Timing Times | 1 to 4 times optional |
| Experimental Data Storage | 350 sets of experimental data |
| Printer | built-in thermal printer |
| Display | 7-inch industrial color touchscreen |
| Power Supply | AC240V±20% 50HZ±10 |
| Dimension | 400 × 380 × 420 mm |
| Packaging Dimension | 650 × 550 × 500 mm |
| Net Weight | 20 Kg |
| Gross Weight | 55 Kg |
Features
Includes a thermal printer for easy use
Can store up to 100 historical records for reference
Enables setting and saving of parameters
Automatically controls temperature
Calculates viscosity values automatically
Compact and benchtop
Built-in autosampler
FAQs
1. What types of fluids can be tested with the Kinematic Viscometer ?
The Kinematic Viscometer is optimized for Newtonian fluids, including diesel, gasoline, base oils, lubricants, hydraulic fluids, transformer oils, and other petroleum-based substances. It can also test chemicals with stable viscosity characteristics across the set temperature range. However, it's not recommended for non-Newtonian fluids like emulsions, slurries, or polymer-thickened materials, as their flow behavior doesn't align with standard capillary test methods. Using the correct capillary size and pre-conditioning samples ensures accurate viscosity readings.
2. How do we choose the right capillary tube for the Kinematic Viscometer ?
It Kinematic Viscometer requires different capillary tubes depending on the viscosity range of the sample. Lower viscosity fluids need smaller tubes, while higher viscosity samples require wider tubes for proper flow during the timing period. The viscometer supports multiple tube sizes, and users can calibrate each one using standard reference oils. Refer to or the product manual to choose the correct tube based on your sample type.
3. Is it possible to test samples at sub-zero temperatures using the Kinematic Viscometer ?
The Kinematic Viscometer allows testing of samples at sub-zero temperatures, with a working range down to –60°C. This feature is useful for checking how fuels and lubricants behave in cold climates or during engine cold starts. The unit uses low-freezing-point bath fluids to maintain stable temperature control. Make sure the correct bath fluid is used to avoid freezing or damage.
4. Can one person manage multiple samples at the same time on the Kinematic Viscometer ?
Kinematic Viscometer can test up to four samples at once, and each sample is handled separately by the system. One person can easily run and monitor all tests at the same time. The system takes care of timing, measurement, and data recording automatically. This helps improve efficiency without needing extra staff.
5. How often should we calibrate the Kinematic Viscometer ?
It Kinematic Viscometer should be calibrated regularly to keep test results accurate. Users should verify calibration with standard viscosity fluids weekly or monthly, based on how often the unit is used. For frequent testing, calibration should be done daily or before every batch. The viscometer allows saving calibration data for different tubes, and any unusual result should be checked with a new calibration or by inspecting the system.