Introduction

Gamma Spectrometer is a portable and digital nuclear monitoring unit with a dose rate of 100nSv/h to 30mSv/h. It utilizes a brominated lanthanum detector and advanced digital nuclear pulse waveform processing technology. Features a large pixel filtering and shaping technology for efficient results.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Gamma Spectrometer provides immediate measurement of environmental γ dose rates and radioactive nuclides. It offers comprehensive nuclide databases categorized into natural, medical, industrial, (Special Nuclear Material), and nuclear materials. It is used in environmental monitoring and other settings.

Specifications

Detector 1.5-inch LaBr₃ Detector, GM tube,Neutron detector
Dose Rate Range 100nSv/h to 30mSv/h
Dose Range 100nSv to 10Sv
Detection Time Nuclides Within 5 Seconds
Mixed Nuclides Within 30 Seconds
Energy Response Range 30keV to 3MeV( γ Radiation)
Energy Resolution ≤ 3.5% at 661.7keV
Confidence Level 70% to 100%
Road Address 1024 roads
Storage Capacity 400000 sets of 1024 spectral data
Communication port
Alarm Functions Low Voltage Alarm
Fault Detection Alarm
Threshold Alarm
Sound And Light Alarm
Battery-Level Monitoring
Working Time >10 hours
Working Temperature -30 ℃ to 50 ℃
Operating Humidity ≤ 90% R.H (35 ℃)
Storage Temperature -50 ℃ to 70 ℃
Power Supply 14.8V lithium-ion rechargeable battery
Dimension 228mm ×124mm ×107mm
Weight 1.5kg

Features

Automatically switches the probe based on the range

Offers power outage protection for the probe

Charger provided for lithium-ion battery

Expandable mid-range detector

Lightweight and highly reliable

Environment-friendly and energy-efficient

Convenient human-computer interaction

Easy to carry out and conduct real-time inspections

Balances energy resolution and pulse pass rate

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.