Introduction

Disinfection Dry Fogger offers broad-spectrum disinfection, effectively targeting bacteria (including both vegetative and spores), viruses, and fungi. It can disinfect the area in a range of 100 m³ to 300m³ with ≥ 25g/min injection rate. It utilizes the high-speed airflow and dry fogging mechanism to spray hydrogen peroxide (H₂O₂) below 8% concentration. It offers rapid, safe, and environmentally friendly decontamination.

This dry fogger is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Disinfection Dry Fogger can effectively disinfect material surfaces and entire clean rooms. It is used in hospital wards, infection departments, operating rooms, negative pressure wards, fever clinics, ambulances, medical examination vehicles, blood donation vehicles, etc.

Specifications

Injection Rate ≥ 25g/min
Airflow Disinfection Capacity 100 m³ to 300m³
Sterilant 8% to 10% food-grade H₂O₂ solution
H₂O₂ Bottle Volume 1 Liter
Monitoring System RH, Temperature, H₂O₂ concentration (Optional)
Display +4.3” Touch Screen
Delay Start 30 S
Alarm Sound and Light
WiFi Control within 50-300meter
Password Control Access 3 levels
Continuous Working Time 3 Hours
Power Consumption 1200W
Power Supply 220 V
Dimensions 380 × 380 × 260 mm
Weight 10 Kgs

Features

Data Record and Print

Integrated RH and temperature sensor

4 Log-6Log reductions of infectious organisms

Automatically operated with one-button start and stop functionality

Capability to store and modify data

Remote control accessibility

Features delay start and appointment start functions

FAQs

1. What are the key factors to consider when selecting this dry fogger for laboratory use?

When selecting this dry fogger, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this dry fogger be calibrated to ensure accurate results?

It is recommended to calibrate this dry fogger at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this dry fogger?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this dry fogger be used with different types of samples, and are there any compatibility considerations?

Yes, this dry fogger can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the dry fogger malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.