Introduction

Tap Density Tester is 03 workstation benchtop unit, designed with cylinder volume of ≤ 250 ml, offers frequency ranges of 300 rpm. Outer surface is plastic coated, strong, resistant, non-corrosive, easy to clean, long working life. Features microprocessor controlled system, built-in micro printer, adjustable-speed motor and vibration assembly. For speed adjustment with range 250 rpm to 300 rpm, it uses speed control adjustment unit. Micro printers print test data such as sample number, volume, operator, weight, tap density and tap number.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Tap Density Tester is widely used to calculate bulk density and test tapped density, Hausner ratio across production, quality, packaging and research testing units in food, pharmacy, medicines and other industries. It is used in life sciences including microbiology, molecular biology, cell biotechnology, immunology and cell.

Specifications

Work Station 3
Sample Volume ≤ 100 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999(set 0 to output bulk density)
Frequency 300 rpm(continuous adjustable in 0 to 300 rpm)
Amplitude Maximum 15 mm(1 to 15 mm integer variable)
Stroke Height Stroke height 3 mm
Strokes / Min 250 strokes / min
Display display
Repeatability ≤ 1 %
Accuracy ≤ 1 %
Humidity ≤ 85 % RH
Motor Torque 0.86 N. m
Power 40 W
Power Supply AC 220 V ± 10 %, 50 Hz
Packing Dimension 560 x 400 x 400 mm
Gross Weight 21.5kg

Features

display for ease of monitoring

Integrated with three station unit

Easy operation, compact structure design and stable

Highly advanced result interpretation

Easy to clean, anti-corrosive, resistant, long lasting

Automatic savings of test results

Integrated with micro printers to print test data

Built in with rpm adjustment and drop height adjustment

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.