Introduction
Ultrasonic Homogenizer (Sonicator) is a table-top, multi-function & multi-purpose unit, comes with 800 ml of process capacity and adjustable ultrasonic power of 10 to 1000 W. Features 0 to 100°C of temperature control range with adjustable time range and 20 to 25 kHz frequency with automatic tracking. Incorporated with 4.3 inch touch screen, data storage for up to 20 sets and print function, this unit has self-diagnostic function along with login password protection With Φ6 mm horn, this ultrasonic homogenizer uses high strength ultrasonic power for cavitation effect in liquid and for material ultrasonic processing with protection against program automatic error, over-load, and over- temperature.
This ultrasonic homogenizer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Ultrasonic Homogenizer Sonicator is used for emulsification, separation, smoothing, extraction, anti-foaming, clear, nano-materials preparation, dispersion, and speed up chemical reactions across biology, microbiology, physics, zoology, agriculture, pharmaceutical, chemical, wastewater treatment, nano-materials etc.
Specifications
| Ultrasonic power | 10 to 1000 W; Adjustable |
| Disruption capacity | 0.1 to 800 ml |
| Standard probe/horn | Φ6 mm or Φ10 mm |
| Display | 4.3-inch touch screen |
| Input method | Touch control |
| Optional probe/horn | Φ2, Φ3, Φ8, Φ10, Φ12, Φ15, Φ20 mm |
| Operating frequency | 20 to 25 kHz, Automatic tracking |
| Temperature control range | 0 to 100°C |
| Storage memory | 20 sets, print etc |
| Time range | 0 to 99 h 59 m 59 s |
| Ultrasonic On/Off setting | 0.1 to 99.9 s |
| Sound proof box | Illumination, sterilization, automatic lifting function optional |
| Protection device | Self-diagnostic function, program automatic error correction, over-load, over-temperature protection display |
| Login password protection | Yes |
| Power supply | 220/110 V |
| Packaging Dimension (Host machine + accessories) | 570 × 460 × 340 mm |
| Gross Weight (Host machine + accessories) | 19 kg |
| Packaging Dimension (Sound proof enclosed box) | 570×400×400 mm |
| Gross weight (Sound proof enclosed box) | 11 kg |
Features
A table-top, multi-function & multi-purpose unit, comes with 800 ml of process capacity
Φ6 mm or Φ10 mm horn size with high strength ultrasonic power
0 to 100°C of temperature control range with adjustable time range
20 to 25 kHz frequency range with automatic tracking
4.3 inch touch screen with touch control input method
Data storage for up to 20 sets and print function
Protection against program automatic error, over-load, and over- temperature
Self-diagnostic function along with login password protection
Easy-to-use, durable and convenient
FAQs
1. What are the typical applications of the It Ultrasonic Homogenizer (Sonicator) in laboratory and industrial settings?
The Ultrasonic Homogenizer (Sonicator) is widely used for tasks such as emulsification, dispersion, extraction, and nano-materials preparation. With a process capacity of up to 800 ml, it is suitable for both small-scale lab research and medium-scale production. Fields such as biotechnology, pharmaceuticals, agriculture, and chemical processing benefit from its versatility. It also supports speeding up chemical reactions and improving uniformity in complex mixtures.
2. How does the Ultrasonic Homogenizer (Sonicator) ensure precise control over sample processing?
Ultrasonic Homogenizer (Sonicator) includes an adjustable ultrasonic power range from 10 to 1000 W and a time control setting from 0.1 to 99.9 seconds, which allows users to finely tune the intensity and duration of sonication. Additionally, it features a wide temperature control range from 0 to 100°C, ensuring optimal conditions for heat-sensitive samples. These controls enable consistent and reproducible results. Users can adapt processing parameters based on sample type and research goals.
3. How does the Ultrasonic Homogenizer (Sonicator) promote safe and reliable operation during prolonged use?
Ultrasonic Homogenizer (Sonicator) features multiple safety mechanisms, including over-temperature protection, overload protection, and automatic error correction. These systems protect both the equipment and the samples during long or intense sonication sessions. Additionally, its self-diagnostic function provides alerts in case of malfunctions, minimizing downtime. The safety features contribute to a stable and dependable operating experience.
4. Is this Ultrasonic Homogenizer (Sonicator) suitable for shared lab environments or quality-controlled operations?
Yes, our Ultrasonic Homogenizer (Sonicator) includes login password protection to restrict access and prevent unauthorized parameter changes. This is essential in labs where multiple users share the same equipment. It ensures process integrity, safeguards preset protocols, and supports compliance with lab management standards. The system also enhances traceability and accountability in regulated environments.
5. What maintenance practices are recommended for optimal performance of the Ultrasonic Homogenizer (Sonicator) ?
The Ultrasonic Homogenizer (Sonicator) should be regularly cleaned the probe and checked for wear or residue buildup after each use. The display, cables, and connectors should be inspected for signs of damage. Users should avoid extended use at maximum power settings to prolong the lifespan of internal components. These guidelines will help ensure reliable long-term operation.