Introduction

A horizontal laminar flow cabinet is a clean bench that provides the horizontal laminar airflow for the protection of the samples and the work area from the contamination, and it is used in the biology, the pharmaceutical, the clinical, the electronics, and the many other applications. The horizontal laminar flow cabinet consists of a work surface, a high efficiency particulate air (HEPA) filter, a fan, and the housing, and it draws the room air through the HEPA filter, providing the horizontal laminar airflow across the work surface, which protects the work area from the airborne contaminants; the horizontal laminar flow cabinet is used for the preparation of the sterile media and the reagents, for the handling of the cell cultures, for the preparation of the samples, for the assembly of the electronic components, and for many other applications, and it is available in various sizes; the horizontal laminar flow cabinet provides a clean work environment, and it is an essential equipment for the clean work. Horizontal laminar flow cabinets are used in the biology laboratories, in the pharmaceutical industry, in the clinical laboratories, in the electronics, and for many other applications. With their laminar airflow, horizontal laminar flow cabinets are essential for the contamination-free work.

Horizontal Laminar Flow Cabinet LHAC-T2010

Horizontal Laminar Flow Cabinet LHAC-T2010



Horizontal is one sided work bench device, operator can sit side by side. It offers 750 mm work surface height and maximum opening up to 430 mm. Device is designed with 01 unit each of w...
Horizontal Laminar Flow Cabinet LHAC-T2011

Horizontal Laminar Flow Cabinet LHAC-T2011



Horizontal is one sided work bench device, operator can sit side by side. It offers 750 mm work surface height and maximum opening up to 430 mm. Device is designed with 01 unit each of w...

Standards

Complies with the above standards, but is not limited to them.

Features

1. Horizontal laminar flow cabinet for providing clean, particle-free work environment.

2. Horizontal airflow with HEPA filtration for product protection in clean work zone.

3. Suitable for electronics, pharmaceutical, biological and laboratory applications.

4. Includes pre-filter, HEPA filter, blower, work surface and illumination.

5. Provides ISO Class 5 (Class 100) clean air for sensitive work and assembly.

FAQ

Q1: What testing scenarios is this cabinet mainly applied to?

A: The horizontal laminar flow cabinet is used in electronics manufacturing, pharmaceutical compounding, biological research, laboratory testing, medical device assembly and precision industries to provide a clean, particle-free horizontal laminar airflow work environment for product protection. It supports sterile compounding in pharmacies, electronics assembly and repair of sensitive components, biological sample handling and tissue culture (where appropriate), medical device assembly, optical instrument assembly, and general laboratory work requiring particulate-free air. The horizontal airflow blows HEPA-filtered air from the back of the cabinet toward the operator, protecting the product from contamination but not the operator. It is essential for pharmaceutical compounding, electronics manufacturing, medical device assembly, biological laboratories and precision industries requiring a clean, particle-free work environment for product protection, sterile preparation, sensitive assembly, contamination-free handling and quality control, where HEPA-filtered laminar airflow provides a consistently clean work zone for products and processes sensitive to particulate contamination in pharmaceutical, electronic, medical and laboratory applications.

Q2: What standards does the cabinet comply with?

A: The horizontal laminar flow cabinet complies with ISO 14644 for cleanroom classification (typically ISO Class 5), relevant NSF/ANSI standards for biological safety cabinets (note: horizontal laminar flow is NOT a biosafety cabinet), and applicable GB/T standards for clean air equipment. HEPA filter efficiency follows EN 1822 or IEST standards. Pharmaceutical compounding follows USP 797/800 where applicable. Users should note this cabinet provides product protection, NOT operator protection from hazardous materials.

Q3: What is the warranty period for the whole machine and key components?

A: The whole cabinet is covered by a 12-month warranty. The blower, work surface, lighting and control are covered, while HEPA filters, pre-filters and gaskets are consumables excluded from warranty. Damage from improper use, filter neglect or unauthorized modification is excluded. Extended service contracts are available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires basic training in clean work technique, filter maintenance and appropriate use. We provide an operation manual and remote guidance. Proper work practices, filter replacement schedule, airflow monitoring and understanding of product vs. operator protection are important for effective and safe use.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular maintenance required? What is the recommended calibration cycle?

A: HEPA filter integrity testing (DOP/PAO test) recommended annually or per regulatory requirements. Pre-filter replacement per schedule or when dirty. Airflow velocity and uniformity verification every 6-12 months. Work surface and interior cleaning regularly. Full certification by qualified personnel for regulated applications (pharmaceutical compounding, medical device manufacturing).

Q7: Are supporting consumables universal?

A: HEPA filters, pre-filters and gaskets are available from the manufacturer or authorized distributors, though compatibility should be verified. Long-term consumable and service cost includes periodic HEPA filter replacement and certification.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes cabinet size, filter type (HEPA, ULPA), work surface material, blower type, lighting and accessories. Additional filters, work surfaces and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the cabinet with an operation manual. On-site installation, filter certification, airflow testing and training are recommended for regulated applications and can be arranged at additional cost. Remote guidance is provided.

Q10: What types of work are compatible with this equipment?

A: The horizontal laminar flow cabinet provides product protection for non-hazardous, non-volatile materials including sterile compounding, electronics assembly, medical device assembly and general clean work. It MUST NOT be used for hazardous chemicals, toxic materials, infectious agents, volatile substances or any application requiring operator protection (those require a fume hood or biosafety cabinet). Users should understand the airflow direction (toward the operator), use only non-hazardous materials, maintain proper work practices (minimize movement, keep items away from front grille), replace filters per schedule, have the cabinet certified regularly, and never use this cabinet for applications requiring operator protection from hazardous or infectious materials.