Introduction

Liquid Chromatography Mass Spectrometry provides higher selectivity, accuracy, and reproducibility, and better limits of detection and quantification. Include a stronger ion source with excellent ionic yield with a mass range between m/z 2 to 2,000. Improved with a new-generation step scan ion transmission technology increasing sensitivity. Configured standard method library, automatic tuning, intelligent , and intelligent batch processing. Built with customized report output functions, simple and easy-to-use control software.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

It is an indispensable tool for quantitative and qualitative analysis in a wide range of fields, from pharmaceuticals and food science to environmental analysis. The applications include identification confirmation of organic chemical compounds, chemical residue analysis, trace level contamination or adulteration detection, and quantitation.

Specifications

Mass Range m/z 2 to 2,000
Resolution R < 0.7 u and adjustable to 0.5 u
Scan Speed ≥2,0000 amu/s
Ionization Switching Time 20 ms
Transition Speed 300 /s
Ion Focus Unit probe with focus electrodes
Recoveries More than 90%
Dimensions 460 × 850 × 650 mm
Net Weight 120 Kg
Gross Weight 150 kg

Features

Unique biorthogonal and dual ion sources for convenient analysis of polar or non-polar compounds

High-efficiency desolvation ion source and ion interface enhance the system tolerability and stability

Include Automatic tuning and mass calibration which reduces the complexity

Built-in with a multi-level vacuum system based on the molecular pump and backing pump

Interlocking control is adopted for all gas circuits, voltage, and heating, ensuring equipment safety

Structured with a 3Q quadrupole transmission system to maintain transmission efficiency

Gold-plated pure molybdenum quadrupole mass analyzer, providing optimal thermal stability

Supplied with full scan, , , , product ion scan, precursor ion scan, and neutral loss scan

Innovative pulse-detection technology can effectively improve the signal-noise ratio and obtain better analysis results

Powerful, friendly mass expert analysis workstation providing brand-new user experience and no-barrier learning

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.