Introduction
Thermo-Shaker Dry Bath a microprocessor controlled thermo-shaker dry bath offers RT+5°C to 100°C temperature range and 200 to 1800 rpm shaking speed range. It structures unique design, compact size, and portable nature. Designed with and auto stop shaking after program completion, temperature calibration function etc.
This thermo-shakers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Thermo dry bath shaker has wide applications in fields like molecular biology, genetic engineering, histology, clinical, environmental and industrial settings. Used for preservation and reaction of sample, amplification of , etc.
Specifications
| Temperature Setting Range | 0°C to 100°C |
| Temperature Range | RT +5°C to 100°C |
| Timer Range | 1 min to 99 h 59 min |
| Temperature Accuracy | ≤ ± 0.3°C |
| Display Accuracy | 0.1°C |
| Temperature Uniformity | ≤ ± 0.3°C |
| Shaking Speed Range | 200 to 1800 rpm |
| Amplitude (Orbit) | 3 mm |
| Heating time | ≤12 mins (from 25°C to 100°C) |
| Multi Points Running | Yes (Max 5 points) |
| Multi Points Running Circularly | Yes (Max 99 times) |
| Auto Heating | Yes |
| Auto Running | Yes |
| Auto Resume To Run | Yes |
| Fuse | 250 V 1A/2A Φ 5 × 20 |
| Power Supply | AC 220 V or AC 110 V, 50 Hz/60 Hz |
| Power | 150 W |
| Dimension | 260 × 195 × 150 mm |
| Net Weight | 7 kg |
Features
Microprocessor controlled system
display shows set and real time and temperature, time and shaking speed
Brushless DC motor, noiseless operation, long service life
Sample block can be easily removed for cleaning or replacement
Offers excellent temperature accuracy and uniformity
Assorted Blocks for wide range of tube sizes
Beep-signal and auto stop shaking after program completion
Temperature calibration function
Over temperature alarm protection
Confirmed to CE standard
FAQs
1. What are the key factors to consider when selecting this thermo-shakers for laboratory use?
When selecting this thermo-shakers, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this thermo-shakers be calibrated to ensure accurate results?
It is recommended to calibrate this thermo-shakers at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this thermo-shakers?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this thermo-shakers be used with different types of samples, and are there any compatibility considerations?
Yes, this thermo-shakers can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the thermo-shakers malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

