Introduction

Portable pH meter is equipped with advanced amplified pH probe and a built-in temperature sensor to measure pH, mV as well as temperature of the solution. This economic pH meter comes with 2 points push button calibration along with auto-buffer recognition to maintain accuracy of test sample readings. The data hold function freezes current reading for easy observation of the test results. It is in accordance with standards. This ph meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

The portable pH meter has applications in waste water treatment & water management, aquaculture, food & beverage processing, environmental monitoring & research and educational purpose.

Specifications

pH range (-2.00) to 16.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points
Calibration solutions (pH 4.01 / 7.00 / 10.01),
Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
mV range (-1999) to 1999 mV
mV accuracy ± 1 mV
mV resolution 1 mV
Temperature measuring range 0 to 100 °C, 32 to 212 °F
Temperature accuracy ± 1 °C
Temperature resolution 0.1 °C
Hold function Manual
Storage/memory Stores up to 50 data sets
Communication output
Connector
Dimension (L × W × H) 185 × 88 × 32 mm
Weight 300 g
Battery life About 150 hours
Power 9 V / 800 mA battery

Features

Wide measurement pH range: (-2.00) to 16.00 pH

pH resolution: 0.01 pH

Auto-buffer recognition using 2 points push button calibration

Data hold function freezes current reading for easy viewing and recording

Automatic electrode slope display helps user decide whether to replace sensor

Help message as an operational guide for Quick access to the pH meter

Automatic temperature compensation ensures accurate measured value over the entire range

Expanded memory stores and recalls data up to 50 test readings

Built-in real time clock stamps stored data to meet standard

FAQs

1. What are the key factors to consider when selecting this ph meter for laboratory use?

When selecting this ph meter, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this ph meter be calibrated to ensure accurate results?

It is recommended to calibrate this ph meter at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this ph meter?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this ph meter be used with different types of samples, and are there any compatibility considerations?

Yes, this ph meter can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the ph meter malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.