Introduction

Tissue Embedding Systems enable precise and efficient preparation of tissue specimens for histology and pathology applications. They automate the process of embedding tissue samples in paraffin wax after fixation, dehydration, and infiltration steps, creating solid blocks suitable for microtome sectioning. They are equipped with accurate temperature control, uniform heating surfaces, and user-friendly interfaces to ensure consistent and reproducible results. tissue embedding systems support various cassette formats, making them ideal for diagnostic laboratories, research institutions, and medical facilities.

Tissue Embedding System LTES-T2021

Tissue Embedding System LTES-T2021



Tissue Embedding System consists of a main console with a heater temperature range of ambient to 99℃ and a cryo console. It features a fully automatic program control system that allows...
Tissue Embedding System LTES-T2020

Tissue Embedding System LTES-T2020



Tissue Embedding System consists of a main console with a working temperature range of ambient to 99℃ and a cryo console with a working temperature range of ambient to -20℃. It has a 3...
Tissue Embedding System LTES-T2011

Tissue Embedding System LTES-T2011



Tissue Embedding System has a paraffin chamber with a super large capacity of 4L allowing for the embedding of a large number of specimens simultaneously. It is a fully programmable comp...
Tissue Embedding System LTES-T2010

Tissue Embedding System LTES-T2010



Tissue Embedding System offers power inputs of 650 VA for Main and Thermal Consoles and 200 VA for Cryo Console, operating at 220 V/50 Hz. It features a Main Console with a working tempe...
Paraffin Trimmer T-PAT-S2103

Paraffin Trimmer T-PAT-S2103

Paraffin Trimmer offers compact design with surface temperature of 80°C. It features computer automated control for trimming of paraffin-embedded tissue blocks. Built with long-lasting he...
Paraffin Trimmer T-PAT-S2102

Paraffin Trimmer T-PAT-S2102

Paraffin Trimmer offers compact design with adjustable temperature of 72℃. Built with high-quality stainless steel with teflon-coated heating surface. It features tilted grooved plate for...
Paraffin Dispenser T-PAD-S2100

Paraffin Dispenser T-PAD-S2100

Paraffin Dispenser offers maximum capacity with temperature of 72°C. It features rapid faucet-type wax melting within 1 to 2 hours and thermal protection. Built with stainless steel body ...
Paraffin Wax Dispenser T-PWD-S2100

Paraffin Wax Dispenser T-PWD-S2100

Paraffin Wax Dispenser offers capacity of 10 litres. Its computer-automated control ensures consistent performance and reliable temperature management. It features advanced heating element...
Paraffin Wax Dispenser T-PWD-S2101

Paraffin Wax Dispenser T-PWD-S2101

Paraffin Wax Dispenser is equipped with capacity of 10000 ml. Its working temperature ranges from ambient conditions up to 100°C, enabling consistent thermal control. It features fully au...
Paraffin Trimmer T-PAT-S2101

Paraffin Trimmer T-PAT-S2101

Paraffin Trimmer features preheating time of 5 to 8 minutes. It is equipped with wax collection box with 300 mL capacity for efficient waste management. Its low centre of gravity and ergon...
Paraffin Trimmer T-PAT-S2100

Paraffin Trimmer T-PAT-S2100

Paraffin Trimmer works between 5°C to 40°C. It features rapid preheat time of 5 to 8 minutes, ensuring quick startup for efficient wax removal. Its removable tray with PE liner simplifie...
Tissue Embedding System T-S212TES

Tissue Embedding System T-S212TES


Tissue Embedding System features a 3.2L paraffin reservoir and a 1.4L cassette/molds tray, ensuring ample capacity for high-throughput embedding tasks. It operates within a working temper...
Tissue Embedding System T-S211TES

Tissue Embedding System T-S211TES


Tissue Embedding System is designed with a 6.0 L paraffin reservoir and a 1.6 L cassette/mold tray, ensuring ample wax storage for continuous operation. It features a precise working temp...
Tissue Embedding System T-S210TES

Tissue Embedding System T-S210TES


Tissue Embedding System has a 6L wax cylinder for extended use and high-throughput sample processing. Its adjustable heater temperature range from ambient to 99 °C ensures precise contro...

Standards

ISO 20166-1:2018-Molecular in vitro diagnostic examinations-Specifications for pre-examination processes for FFPE tissue-Part 1: Isolated RNA

Complies with the above standards, but is not limited to them.

Features

1. Easy-to-clean surfaces resist paraffin and stains.

2. Integrated waste tray keeps the cutting area clean.

3. Orientation and trimming functions align the specimen block.

4. Smooth advance and retraction reduce chatter and specimen damage.

5. Accessories for baths, trays and staining support the workflow.

FAQ

What is the Tissue Embedding System mainly used for?

The Tissue Embedding System is used in histology and pathology to prepare tissue sections, process samples and handle slides for microscopic diagnosis. It supports hospital laboratories, research and teaching where thin, consistent sections and clean staining are required.

Which standards and regulations apply to the Tissue Embedding System?

The equipment is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for histology laboratory equipment, with workflows following standard histopathology practice. Compliance documentation can be provided on request.

What does the warranty cover?

The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.

Is the Tissue Embedding System difficult to operate?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Tissue Embedding System need calibration or verification?

Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.

Are consumables and spare parts easy to obtain?

The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.

Can the Tissue Embedding System be customised?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Do you provide on-site installation?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What maintenance and safety points matter?

Do not cut with damaged blades, force the mechanism or handle reagents without protection. Change blades carefully, clean the bath and fix tissue properly. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry