Introduction

Nucleic Acid Extraction System is a completely automated system for extracting and purifying from a range of sources. In just a few minutes, this procedure can handle numerous samples each day and offer quick, consistent, and repeatable findings. In a single run, this small device can handle 32 big volume samples up to a needed quantity. This device is a turnkey solution that provides lab with everything you need to automate high speed purifications. This nucleic acid extraction system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

This device is compatible with diagnostics kits and also has requirement in several fields such as Forensic Samples, Sequencing, Cloning, Routine sample preparation, Genetic screening, Microbiology testing and Plant molecular biology research.

Specifications

Sample Capacity 32 samples
Sample Volume 20 to 500 µl
Working Volume 20 µl to 1000 µl
Sample Throughput 1 to 32
Extraction Time 15 to 40 min/round
Extraction Method Magnetic Bead Recovery
Magnetic Bead Recovery > 98%
Extracting the difference between holes CV ≤ 3%
Heating Temperature 8 independent heating modules, customize lysis and elution temperature
Oscillating Mixing Low, medium and high 3 gears are adjustable and fluctuation range can be adjusted with the reagent volume
Reagent Type Magnetic bead open platform
Internal Program Can store up to > 100 groups of programs
Built-in Air Duct No
UV Radiation Yes
Package Size (W×D×H) 580×510×700 mm
Gross Weight 51 kg

Features

Convenient throughput up to 32 samples in 15 – 40 mints

7-inch touch screen, easy to use console

UV dis-infection function

Archival quality or

Automatic control system

User defined cracking and elution temperature

Fast purification process

Reproducibility with magnetic rods

Plate re-orientation

Lidding and de-lidding

Graphical process editor

Free programming to meet the different needs of the reagent

FAQs

1. What are the key factors to consider when selecting this nucleic acid extraction system for laboratory use?

When selecting this nucleic acid extraction system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this nucleic acid extraction system be calibrated to ensure accurate results?

It is recommended to calibrate this nucleic acid extraction system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this nucleic acid extraction system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this nucleic acid extraction system be used with different types of samples, and are there any compatibility considerations?

Yes, this nucleic acid extraction system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the nucleic acid extraction system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.