Introduction
The Auto Chemistry Analyzer is a desktop machine that works on its own to perform chemical tests, and it can handle 200 tests each hour. With expanded on-board testing, reduced sample volume, and simple operation, this is a suitable chemical analyzer for low to mid-volume hospitals and laboratories worldwide. The easy-to-use interface provides a long-term basis for analytical performance. This system contains standardized test menus, assay methods, instrument operations, and reference ranges, all of which limit operator variation and offer consistent quality results.
This chemistry analyzer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
This device is used in many Biology and Histopathology Laboratories to extract the serum, plasma, urine or any other body fluid, Research institutes etc.
Specifications
| Throughput | 200 tests/hour |
| Sample Volume | 2 to 70 µl |
| Reagent Volume | 20 to 350 µl |
| Sample Positions | 37 sample positions |
| Reagent Positions | 28 reagent positions |
| Absorbance | 0~3.0 Abs |
| Humidity | 30 to 80% |
| Washing | Automatic cuvettes washing |
| Probe Washing | Automatic washing interior and exterior |
| Reagent Cooling | Refrigerated tray with independent switch |
| Cuvettes | 48 reusable cuvettes, optical length 6mm |
| Mixed Probe | Independent stirring |
| Stat Function | Yes |
| Light Source | 6V/10W halogen lamp |
| Spectrophotometry | Post-spectral spectrophotometry |
| Calibration | Linear: K factor, 1-point, 2-point and multipoint linearNon-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 |
| Quality Control | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) |
| Software | Windows 7/8/10, 32 or 64bit |
| System | Bi-direction, support HL7 protocol |
| Interface | port access |
| Printer | External, multiple reporting mode available |
| Temperature | 10 to 30°C |
| Temperature Control | 37±0.1°C, real time monitor |
| Water Consumption | Deionized water: 5 L/H |
| Power Supply | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W |
| External Dimension (W×D×H) | 625×425×460 mm |
| Package Dimension (W×D×H) | 721×531×855 mm |
| Net Weight | 36 kg |
| Gross Weight | 55 kg |
Features
Intelligent software
High quality components
Uninterrupted workflow
Inventory management
Cost effective operation
Crash and collision detection
Robust testing capabilities
Efficient reagent and consumable use
Simplify operations with user friendly graphical user interface design and touch-screen monitor
Refrigerated tray with independent switch
FAQs
1. What makes the Auto Chemistry Analyzer an open system, and why is this beneficial?
The Auto Chemistry Analyzer is designed as an open system, allowing the use of reagents from multiple suppliers instead of being restricted to proprietary options. This flexibility reduces operational costs and ensures easy reagent availability. It supports a wide range of biochemical tests, making it suitable for diverse laboratory needs. The open system design enhances adaptability, helping laboratories maintain smooth operations during supply shortages. It also allows customization of test parameters, increasing efficiency and accuracy. Users can choose preferred reagent brands without compromising performance. The analyzer’s open system feature makes it an ideal choice for small to large laboratories.
2. What is the testing throughput of the Auto Chemistry Analyzer ?
Auto Chemistry Analyzer delivers high-speed analysis with reliable accuracy. It is designed to process multiple samples efficiently, making it suitable for high-volume testing environments. The system automates sample handling to minimize manual work. Its advanced software ensures smooth workflow and consistent results. The throughput helps laboratories save time during busy operations. Faster test cycles improve overall lab productivity. This makes the Auto Chemistry Analyzer an excellent choice for both routine and emergency testing needs.
3. What types of tests can be performed with this Auto Chemistry Analyzer ?
It supports a wide variety of biochemical and clinical chemistry tests. Auto Chemistry Analyzer can analyze serum, plasma, urine, cerebrospinal fluid, and other biological samples. The open system design allows customization of test parameters for different assays. It is widely used for liver, kidney, lipid, and electrolyte profiles. This versatility makes it suitable for hospitals, diagnostic centers, and research labs. The analyzer offers precision and consistency across various test categories. It ensures flexibility for laboratories with diverse testing needs.
4. How user-friendly is the Auto Chemistry Analyzer ?
Auto Chemistry Analyzer is designed with an intuitive touchscreen interface for easy navigation. Its automated functions reduce the need for extensive operator training. Step-by-step prompts guide users through sample loading and result interpretation. The software is simple to use, even in high-pressure testing environments. Maintenance reminders ensure smooth operations without frequent breakdowns. Built-in features minimize human error and improve workflow efficiency. Overall, it’s a highly user-friendly system that enhances productivity in any lab setting.
5. How does the Auto Chemistry Analyzer ensure the accuracy and reliability of results?
Auto Chemistry Analyzer uses advanced optical systems and precise pipetting to deliver accurate results. It is equipped with automated calibration and quality control functions. These features ensure every test run maintains consistent standards. Built-in alarms notify users of potential errors in real time. The analyzer’s high sensitivity reduces the chances of false readings. Its robust design ensures long-term reliability under continuous use. Laboratories can depend on their performance for accurate diagnostic decisions.
6. What sample and reagent volumes does it Auto Chemistry Analyzer require?
The Auto Chemistry Analyzer is designed to work efficiently with minimal sample and reagent volumes. It typically requires 20–350 µL of reagent per test, reducing operational costs. Low-volume testing helps conserve precious samples, especially in critical cases. The flexible sample volume requirement makes it ideal for pediatric and specialized testing. Automated reagent handling ensures precision and consistency. The system’s design supports cost-effective and sustainable laboratory operations. This feature makes the Auto Chemistry Analyzer suitable for labs of all sizes.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.