Introduction

Knife Tissue Grinder is a specialized instrument used for pulverization and homogenization of samples with high moisture, high oil content and high fat content. Adopted with strong industrial motor, stainless steel serrated blade, and safety protection lock, it offers adjustable, high and fast grinding speed of 1000 to 1600 rpm with intermittent mode for up to 700 ml of sample volume. Incorporated electronic control system with click function and program setting, method memory and storage function, ensures sample repeatability and homogenized sample preparation result. With compact design, digital display, timer and various grinding cups, this knife tissue grinder can be equipped with a gravity top cover with an overflow channel and a reduction top cover to compress the space of the grinding chamber, ensures high grinding efficiency. With simple operation and quick start, it is an ideal unit for pulverizing samples to analysis fineness within tens of seconds by relying on high speed and diversified accessories.

This tissue grinder is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Knife tissue grinder is used for effective grinding of dry, soft, elastic, fibrous, fat-containing, water-containing, and oil-containing and medium-hard samples across agriculture, medicines, biology, food industries etc.

Specifications

Sample volume ≤ 700 ml
Sample type Dry, soft, elastic, fibrous, medium-hard, fat-containing, water-containing, and oil-containing
Sample size About 10 to 40 mm
Final sample size About 300 µm
Speed range 1000 to 1600 rpm; adjustable
Timer range 1 sec to 60 min
Operation mode Intermittent operation mode (interruptible)
Storage 10 groups
Display Digital display
Control system Electronic control system
Rotary knife material Stainless steel blade, stainless steel serrated blade
Motor Industrial motor
Safety protection lock Yes
Power 1100 W
Power Supply AC 220 V, 50 Hz
Dimension (W×D×H) 300×310×370 mm
Gross Weight 27.5 kg

Features

Specialized instrument used for pulverization and homogenization

Strong industrial motor, stainless steel serrated blade

Adjustable, high and fast grinding speed of 1000 to 1600 rpm

Intermittent operation mode, safety protection lock

Electronic control system with click function and program setting

Method memory and storage function for up to 10 groups

Digital display with 1 sec to 60 min time setting for convenient operation

Gravity top cover with an overflow channel, for large sample processing

Reduction top cover to compress the space of the grinding chamber

High-efficient with simple operation and quick start

FAQs

1. What are the key factors to consider when selecting this tissue grinder for laboratory use?

When selecting this tissue grinder, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this tissue grinder be calibrated to ensure accurate results?

It is recommended to calibrate this tissue grinder at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this tissue grinder?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this tissue grinder be used with different types of samples, and are there any compatibility considerations?

Yes, this tissue grinder can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the tissue grinder malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.