Introduction

Scroll Vacuum Pump is reliable, durable, oil-free, high performance vacuum pump, combined with lower power consumption and lower ultimate pressures. Offers ambient operation temperature ranges from 41 to 104°F and maximum inlet and exhaust pressure of 0.1 / 0.13 MPa. Designed with air cooling system, air flush and innovative scroll design that reduces vibration and noise. It is suitable to use in molecular pump backing, accelerators and synchrotrons, capacitor exhaust, surface analysis instruments, E-beam and laser melting, spectroscopy and scanning electron, leak detection, space environment animation, glove box and coating , CV and . This vacuum pump is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Scroll Vacuum Pump is widely used in hydrogen fuel cell process, oil vapor recovering, , and Laser tube, load lock and transfer chambers, freeze drying and gel drying, special gas recovery and recirculation, vacuum oven, lithium ion battery process, distillation, purification and filtration and Cryo pump regeneration.

Specifications

Ambient Operation Temperature 41 to 104°F
Maximum Inlet and Exhaust Pressure 0.1 / 0.13 MPa
Leakage 1×10-7mbar·l/s
Cooling Type Air cooled
Noise Level ≤ 52 dB
Others With air flush
Pumping Speed
50 Hz2.0 L/s
  120.0 L/min
  7.2 m3/h
  4.3 cfm
60 Hz 2.4 L/s
  144 L/min
  8.6 m3/h
  5.1 cfm
Ultimate Pressure ≤ 6.0×10-2 mbar
  ≤ 4.0×10-2 Torr
  ≤ 40 micron
  ≤ 9.0×10-4 psi
Motor 1 phase
Power 0.25 kW
Voltage 50 to 60 Hz/110 to 115 or 200 V to 230 V
Speed 50 Hz /1425 rpm; 60 Hz /1725 rpm
Connect North America, Europe, UK, Ireland, India
Motor 3 phase
Power 0.37 kW
Voltage 50 Hz/200 V to 230 V or 380 to 415; 60 Hz/200 V to 230 V or 460 V
Speed 50 Hz /1425 rpm; 60 Hz /1725 rpm
Inlet and Exhaust Flange KF25/16
Dimensions (W×D×H)
1 Phase 405×225×260 mm
3 Phase 445×265×305 mm
Net Weight
1 Phase 15 kg
3 Phase 16 kg

Features

High efficiency, low vibration and low noise

No oil mist exhaust, and no oil back diffusion

Integrated with motor 1 and motor 3 phase

Suitable to use for cleaning processes

Constantly operated between vacuum and atmospheric

Easy to clean, operate and less maintenance

Suitable for various type of power supply around the world

FAQs

1. What are the key factors to consider when selecting this vacuum pump for laboratory use?

When selecting this vacuum pump, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this vacuum pump be calibrated to ensure accurate results?

It is recommended to calibrate this vacuum pump at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this vacuum pump?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this vacuum pump be used with different types of samples, and are there any compatibility considerations?

Yes, this vacuum pump can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the vacuum pump malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.