Introduction
Ethylene Oxide Sterilizer is a vertical , constant temperature heating box type sterilizer cabinet with manual door opening offers 360 kPa work pressure. Sterilization room material is made of 304 anti-corrosion type stainless steel, and outer box material is of carbon steel (thickness1.8 mm) baked plastic powder with electric heating method having automatic ventilation with 30 mins interval once. Built-in temperature; humidity; pressure sensor with automatic control system ensures stability, efficiency and quality. Digital printer prints the whole process of sterilization information for recording and verification check. Explosion-proof electric heating device with over-voltage and over-temperature protection, residual air automatic processing system, reliable operations.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Ethylene Oxide Sterilizer used to sterilize catheters, resuscitation bags, anesthesia masks, most fiber-optic instruments, glassware, solution medium, assembled complex devices, Custom procedure packs, equipment with integrated electronics, multi-lumen tubing products, stents, wound care dressings etc. across the field of pharmaceutical industries, metal & glass industries, hospitals, laboratories and research institutes etc. This autoclave most suits for prosthetic implants (joint, hip and knee replacements) sterilization.
Specifications
| Type | Vertical; constant temperature heating box type |
| Door opening | Manual |
| Capacity | 360 L |
| Sterilization temperature | 50℃ ± 3℃ |
| Work pressure | -60 kPa |
| Maximum pressure | -140 kPa |
| Humidity (sterilization) | 45% to 75% |
| Sterilizing gas | Ethylene oxide; 1g/L |
| Sterilization time | 3 to 99 hrs; adjustable |
| Vacuum speed | -60 kPa in 15 mins |
| Ventilation | Automatic |
| Ventilation cycle | 3 times; 30 mins interval once |
| Control system | Automatic; one-button |
| Display | Digital display |
| Printer | Yes |
| Humidity sensor | Yes; cavity humidity: >45% RH |
| Pressure sensor | Yes |
| Temperature sensor | Yes; cavity temperature: 50℃ ± 3℃ (within precise range) |
| Vacuum system | Oil free vacuum pump |
| Heating system | Electric; explosion-proof electric heating device |
| Alarm system | High/low temperature |
| Protection features | over-voltage, over-temperature protection, residual air automatic processing system |
| Sterilization room material | 304 anti-corrosion type stainless steel |
| Outer box material | Carbon steel (thickness 1.8mm) baked plastic powder |
| Wear parts | Seal |
| Caster | Yes |
| Power | 3.6 kW |
| Chamber dimensions (W×D×H) | 600×830×730 mm |
| Dimensions (W×D×H) | 820×1010×1380 mm |
| Weight | 340 kg |
Features
Vertical, constant temperature heating box type ethylene oxide sterilizer cabinet with manual door opening
304 stainless steel and carbon steel baked plastic powder for sterilization room and outer box respectively with electric heating method
Automatic ventilation, 3×cycle ventilation with 30 minutes interval once
Digital display with automatic control system and printer
Built in sensor: humidity; pressure; temperature for precise and effective control
Oil-free vacuum pump; explosion-proof electric heating device for convenience
High and low temperature alarm system
Incorporated with casters for easy movements
Sealed wear parts
Simple and convenient operation with long service life
FAQs
1. What safety features are included in the Ethylene Oxide Sterilizer?
Ethylene Oxide Sterilizer is designed with multiple safety features, including automatic pressure and temperature controls. The explosion-proof heating device prevents overheating during operation. High and low-temperature alarms ensure safe sterilization cycles. The built-in ventilation system removes residual gas, reducing exposure risks. Additionally, the outer casing is made of durable materials to enhance operational safety.
2. How efficient is Ethylene Oxide sterilization compared to other methods?
Ethylene Oxide Sterilizer provides an advanced sterilization solution for heat-sensitive and moisture-sensitive items. Unlike steam sterilization, it operates without high temperatures or pressure, ensuring the safety of delicate instruments. The gas penetrates deeply into complex medical devices, guaranteeing thorough sterilization. It effectively eliminates all microorganisms, including resistant bacterial spores. This makes it one of the most dependable sterilization methods available.
3. Can the sterilizer be used in a confined space?
Ethylene Oxide Sterilizer should always be used in a well-ventilated area to ensure safe operation. Proper aeration effectively removes any residual gas after sterilization, preventing harmful exposure. The built-in safety mechanisms regulate gas release, ensuring controlled emission and reducing accumulation risks. If used in enclosed spaces, an exhaust ventilation system is necessary to maintain air quality. Regular monitoring of gas levels and following safety protocols help create a secure working environment.
4. How can I ensure the long-term efficiency of an Ethylene Oxide Sterilizer?
To maintain long-term efficiency, It advises regular servicing and preventive maintenance of the Ethylene Oxide Sterilizer. Key components such as sensors, ventilation systems, and gas flow regulators should be inspected periodically. Proper cleaning prevents residue buildup, ensuring safe and effective sterilization cycles. Checking and replacing worn-out door seals and filters helps maintain airtight conditions. Scheduled maintenance enhances performance, extends equipment lifespan, and ensures consistent sterilization quality.
5. Is Ethylene Oxide Sterilization suitable for intricate medical instruments?
Sterilizing intricate medical instruments requires a method that reaches every internal surface. Ethylene oxide sterilization utilizes gas diffusion to penetrate fine tubing, lumens, and electronic components effectively. This low-temperature process is ideal for delicate equipment that cannot withstand heat or moisture. Its controlled sterilization cycle ensures even gas distribution, eliminating all harmful microorganisms. As a result, it is a preferred solution for endoscopes, multi-lumen devices, and precision surgical tools.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.