Introduction

Microbial Air Sampler is equipped with impactor technology for precise collection of airborne microorganisms. Their high-efficiency sampling function ensures optimal performance in capturing bioaerosols. They offer adjustable flow rate control for customized sampling in various environments. These samplers support easy integration with agar plates and filters for microbiological analysis. Our Microbial Air Sampler provides real-time contamination detection for fast, reliable results.

Microbial Air Sampler T-S2L-S2101

Microbial Air Sampler T-S2L-S2101

Microbial Air Sampler offers sampling volume range from 1 to 9999 L. It features a 400-hole configuration with 0.6 mm aperture for uniform particle distribution. Equipped with loop, delay,...
Microbial Air Sampler T-S2L-S2100

Microbial Air Sampler T-S2L-S2100

Microbial Air Sampler collects air at 100 liters/min with a sampling range of 0.01 to 9.0 m³. air sampler is enhanced with multi-jet holes each with a flow rate of 0.38m/s. It provides pr...
Microbial Air Sampler T-S210MAS

Microbial Air Sampler T-S210MAS


Microbial Air Sampler features a stable aspiration rate of 100 liters per minute, ensuring efficient air sampling. It has 400 holes with an aperture of 0.6 mm and achieves an impact veloc...
Microbial Air Sampler MS2020

Microbial Air Sampler MS2020


Microbial Air Sampler offers a programmable sampling volume range from 0.001 to 9.999 m³. It operates at a flow rate of 100 L/min, with a sampling head speed of 0.38 m/s. Integrated with...

Standards

ISO 14698-1:2003-Cleanrooms and associated controlled environments-Biocontamination control-General principles and methods

EN 17141:2020-Cleanrooms and associated controlled environments-Biocontamination control

Complies with the above standards, but is not limited to them.

Features

1. Clear display shows flow, time and sample volume.

2. Data storage and export support monitoring records.

3. Easy cleaning and decontamination between sites.

4. Accessories for media and stands are available.

5. Timed sampling programs follow standard protocols.

FAQ

What are the main applications of the Microbial Air Sampler?

The Microbial Air Sampler is used to collect airborne particles, microorganisms or aerosols for environmental and hygiene assessment. It supports cleanrooms, hospitals, food plants, occupational hygiene and laboratories monitoring air quality.

Which standards and regulations apply to the Microbial Air Sampler?

The sampler is designed with reference to applicable ISO and GB/T air-sampling and cleanroom monitoring methods and IEC 61010 electrical safety. Flow and media should follow the standard. Compliance documentation can be provided on request.

How long is the warranty period?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

How easy is the Microbial Air Sampler to use?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.

Where do we get replacement parts?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Are options or configurations available?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What maintenance and safety points matter?

Do not use an uncalibrated flow, blocked inlet or contaminated media, and avoid sampling in unsuitable conditions. Verify flow and follow hygiene procedures.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry