Introduction

Real Time is a portable unit comes with sample capacity of 16×0.2 ml (2×8 well, double block), offers emission wavelength ranges from F1: 520 to 540 nm and factory calibrated dyes of F1: / Green l. Adopted with American Marlow customized Peltier module, single channel and double 8-wells blocks design with analysis software that can run two different design at a same time. Built in with high sensitivity photoelectric detector, 7 inch color touch screen display of 1280×800 pixels with win 10 operating system and long life excitation. Equipped with powerful software analysis function such as, genotyping, melting curve, absolute and relative quantification.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Real Time is widely used in scientific research in biological laboratories, rapid diagnosis of disaster and epidemic diseases, inspection and quarantine in the field of food safety. It is suitable to use for real time detection in breeding farm, pasture, water sources and forest farm.

Specifications

Sample Capacity 16×0.2 ml (2×8 well, double block)
Consumable Clear 0.2 ml tube/ 8-tube strips
Reaction Volume 10 to 100 µl
Excitation Wavelength 460 to 550 nm
Emission Wavelength F1: 520 to 540 nm
Display 7 inch color touch screen , 1280×800 pixels
Temperature Control Technology Marlow customized Peltier allow 1.000.000 cycles
Temperature Range 0 to 100°C (Resolution: 0.1°C)
Maximum Ramp Rate 6°C/s
Temperature fluctuation ± 0.1°C
Uniformity ± 0.25°C
Accuracy ± 0.25°C
Hot Lid Temperature 30 to 115°C (Adjustable, default 105°C)
Temperature Control Block/Tube
Factory Calibrated Dyes F1: / Green l
Excitation Long life
Detection High sensitivity photoelectric detector
Dynamic Range 1 to 1010 copies
Sensitivity 1 Copy
Feature Function Absolute /Relative Quantification, melting curve, genotyping
Date Export Formats Excel, , txt
Printing Report can be printed (Optional thermal printer)
Communication Parts / 2.0
Power DC 15 V, 250 W
Dimension (L×W×H) 300×267×198 mm
Net Weight 5.5 kg
Gross Weight 8 kg

Features

7 inch color touch screen display with 10 operating system for ease of monitoring various parameters

It is Single Channel Real Time Machine

Equipped with environmental protection, energy saving and light source

Adopts the same acquisition optical path to improve the repeatability

Easy to carry, light weight and compact design

Provide flash memory of 20 G, saves experimental data of upto 40000 pieces

Built in with back reaction block, side scan technology and electromagnetic lock cover technology

Offers long service life and free maintenance

Integrated with front shutdown button to secure file data

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

1. What is the software like, and how does it support data analysis?

Real Time is controlled via user-friendly PC software that provides an intuitive interface for experiment setup, monitoring, and data analysis. The software allows users to define thermal cycling protocols, manage multiple fluorescence channels, and visualize amplification curves in real-time. Post-run analysis features include quantification, melting curve analysis, and data export for further processing. The software supports repeatable analysis and rapid data collection, ensuring that even complex datasets are easy to interpret.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.