Introduction
Microwave Digestion System is a self-vent and reseal structured unit with multi safety protection functions. The continuous rotating reduces impact on rotary motor which greatly extends the service life of rotor motor. material for inner vessel and glass material for outer vessel prevents corrosion. Contact free temperature and pressure measurement avoids cross contamination.
This microwave digestion system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Used to dissolve compounds such as heavy metals, inorganic compounds, filters and sediments in food, textile, plastic, geology, metallurgy, coal, bio-pharmaceutical, petrochemical, environmental monitoring, wastewater treatment, battery manufacturing, cosmetics and other fields.
Specifications
| Sample quantity | 18 per batch |
| Chamber volume | 100 ml |
| Rotation mode | 360° continuous rotation |
| Microwave power | 0 to 3000 W adjustable |
| Microwave frequency | 2450 MHz |
| Pressure control range | 0 to 15 MPa |
| Maximum working pressure | 6 MPa |
| Pressure control accuracy | ± 0.01 MPa |
| Outer vessel pressure limit | 20 MPa |
| Temperature control range | 50 to 400 °C |
| Maximum working temperature | 250 °C |
| Temperature control accuracy | ± 0.1 °C |
| Inner vessel temperature limit | 300 °C |
| Microwave leak | < 5 mW / cm5 |
| Inner vessel material | |
| Outer vessel material | + glass fiber |
| Explosion proof frame | Polypropylene Glass Fiber |
| Temperature testing | Contactless |
| Pressure testing | Contactless |
| Display | 8 inch touch screen |
| Power | AC 220 V 16A , 50 Hz / 60 Hz |
| Main Unit Dimension | 800 x 800 x 810 mm |
| Configuration Box Dimension | 570 x 570 x 660 mm |
| Main Unit Net Weight | 77 kg |
| Configuration Box Net Weight | 17 kg |
| Main Unit Gross Weight | 110 Kg |
| Configuration Box Gross Weight | 38 Kg |
Features
Reseals instantly when a sudden over pressurization occurs
Adopts multi-fiber to monitor pressure in a contactless way
All temperature and pressure data are displayed real time during the microwave run
Large storage capacity- can edit and store 255 programs
Uniform heat distribution by diffuser for sample digestion
Alarm sensor for detection of abnormal pressure and temperature
Real time pressure and temperature curve
Automatic calibration and troubleshooting
Vertical pressure release for safe operation
High strength double security door
Instrument fault monitoring alert
Instrument abnormal sound monitoring
Multiple safety protection functions including temperature and pressure control, explosion-proof security doors, lid-locking and real-time temperature
FAQs
1. What are the key factors to consider when selecting this microwave digestion system for laboratory use?
When selecting this microwave digestion system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this microwave digestion system be calibrated to ensure accurate results?
It is recommended to calibrate this microwave digestion system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this microwave digestion system?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this microwave digestion system be used with different types of samples, and are there any compatibility considerations?
Yes, this microwave digestion system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the microwave digestion system malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.