Introduction

Microwave Digestion System is newly designed and fully upgraded with higher performance and safer protection system. Vessel quantity of 6 and vertical design for even distribution of microwave with multi safety protection functions. Equipped with contactless sensor monitoring with no burst disk design saves consumables cost and maintenance cost. Designed with 7 inch color touch screen with user-friendly interface for easy operation. Material used material for inner vessel and glass material for outer vessel prevents corrosion. Offers free temperature and pressure measurement avoids cross contamination. It is used to dissolve compounds such as heavy metals, inorganic compounds, etc.

This microwave digestion system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Microwave Digestion System is used to dissolve compounds such as heavy metals, inorganic compounds, filters and sediments in food, textile, plastic, geology, metallurgy, coal, bio-pharmaceutical, petrochemical, environmental monitoring, wastewater treatment, battery manufacturing, cosmetics and other fields.

Specifications

Vessel Quantity 6
Temperature Monitoring System Contactless IR Sensor, scan monitoring for each vessel
Temperature Controlling Range 50 to 400℃
Display Accuracy ± 0.1℃
Temperature Display Accuracy ± 0.1℃
Pressure Monitoring System Contactless Sensor, scan monitoring for each vessel
Pressure Controlling Range 0 to 15 MPa
Pressure Accuracy ±0.01 MPa
Pressure Display Accuracy ±0.01 Mpa
Vessel Volume 100 mL
Sample Vessel Material Imported
Protection Vessel Material Peek+ Glass Fiber
Display 7 inch Touch Screen
Rotation 360° Continuous rotating
Microwave Tank 316 L stainless steel tank with corrosion-proof coating
Microwave Power 0 to 1000 W (Adjustable)
Microwave Leakage < 5 mw/cm2
Air Exhaust High power corrosion-proof air blower
Dimension 490 × 560 × 630 mm
Power AC 220V±10%, 10A, 50/60 Hz
Weight 47 kg

Features

Offers vessel quantity of 6 vessels to meet different digestion requirements

Vertical design for even distribution of microwave

Its controlling temperature ranges from 50 to 400℃

Pressure controlling range is 0 to 15 MPa

Equipped with contactless sensor monitoring with no burst disk design saves consumables cost and maintenance cost

Real-time monitoring for both temperature and pressure of each vessel

Imported vessel material for both sample vessel and protection vessel highly ensures safety

Designed with 7 inch color touch screen with user-friendly interface for easy operation

Adopts outer shell material with high strength ensures impact resistance

Pre-installed general standard methods to save, modify and delete the method

Material used 316 L industrial stainless steel tank with multilayer teflon coating avoids acid corrosion, also improved cooling efficiency

FAQs

1. What are the key factors to consider when selecting this microwave digestion system for laboratory use?

When selecting this microwave digestion system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this microwave digestion system be calibrated to ensure accurate results?

It is recommended to calibrate this microwave digestion system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this microwave digestion system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this microwave digestion system be used with different types of samples, and are there any compatibility considerations?

Yes, this microwave digestion system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the microwave digestion system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.