Introduction

Ion chromatograph system is a modular design ion chromatograph with high column efficiency and large column capacity and stable performance. With large conductivity detection range, it delivers more accurate results. Bipolar conductivity detector, improves the detection performance and stability of the instrument. Built-in circulating stereo constant temperature, and other technologies ensures accurate and reliable experimental data. This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Used to detect small molecules (in the form of anion, cation) in food, chemical, mining, metallurgy, environment and other fields.

Specifications

Ion Chromatographic Pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa ()
Pressure display accuracy ≤ 0.1 MPa
Flow stability (0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow range 0.001 to 9.999 ml/ min
Pressure pulse ≤ 0.5%
Conductivity detector
Type Temperature Control and Bipolar Conductivity Detector
Detection mode Bipolar conductivity detection
Cell volume ≤ 0.8 µL
Detection range 0 to 45000 µS/ cm
Detection resolution ≤ 0.0020 nS/ cm
Output voltage - 6000 to +6000 mV (adjustable)
Baseline noise ≤ 0.05 % F.S.
Baseline drift ≤ 3 % FS/ 30 min
Operating temperature range Room temperature +5 to 60°C (41 to 140°F)
Controlling temperature accuracy ± 0.01°C
Maximum pressure 10 MPa
Linear range ≥ 103
Instruments linearity ≥ 0.999
Quantitative repeatability ≤ 1.0 %
Qualitative repeatability ≤ 1.0 %
Minimum detectable concentration Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow system
Plastic flow path Made of materials
Six way Valve material, 5000 psi pressure, independent automatic collection and flow function
Power supply 150 W
External dimension 350 × 470 × 510 mm
Net weight 26 kg
Gross weight 32 kg

Features

Large column capacity to detect various component ions

Maintains excellent system stability

Temperature controlled bipolar conductivity detector

Automatic, self-regenerating electrolytic microfilm suppressor

Intelligent workstation controls

RS232, Interface

User-friendly operations

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.