Introduction

Automatic Oil Dielectric Tester has capacity of testing up to 20 kV for dielectric strength. They ensure reliable assessments of insulating oils and liquids under controlled conditions. Their advanced microprocessor technology enables automatic operation and reliable readings. They feature clear display for easy reading and include safety system to protect against overloads. Automatic Oil Dielectric Tester are essential for evaluating insulation quality of transformer oils and other dielectric fluids.

Automatic Oil Dielectric Tester T-S2DT-S2101

Automatic Oil Dielectric Tester T-S2DT-S2101

Automatic Oil Dielectric Tester delivers output voltage from 0 to 80 kV for reliable testing. It adopts microprocessor for fully automatic execution of boosting, holding, stirring, static...
Automatic Oil Dielectric Tester T-S2DT-S2100

Automatic Oil Dielectric Tester T-S2DT-S2100

Automatic Oil Dielectric Tester is designed to assess the dielectric strength of insulating oils. The oil tester is fully automated and utilizes industrial Single-Chip Microcontroller (SCM...

Standards

IEC 60156:2018-Insulating liquids-Determination of the breakdown voltage at power frequency-Test method

ASTM D877-Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes

ASTM D1816-Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes

Complies with the above standards, but is not limited to them.

Features

1. Clear labelling and colour-coded controls reduce operator error.

2. Rugged, field-tested construction holds up under daily laboratory use.

3. Safety devices protect samples, the unit and the operator.

4. Low running costs and no locked consumable requirement.

5. Clear controls and display support straightforward operation.

FAQ

What are the main applications of the Automatic Oil Dielectric Tester?

The Automatic Oil Dielectric Tester is used for a defined laboratory measurement, preparation or processing task. It supports analytical, quality-control, research, clinical or industrial work where consistent, repeatable results are required.

What standards does the Automatic Oil Dielectric Tester comply with?

The instrument is designed with reference to IEC 61010 electrical safety, the applicable international standard for the measurement or process and relevant GB/T standards. Procedures should follow the relevant method. Compliance documentation can be provided on request.

What does the warranty cover?

The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.

Will staff need special training?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.

Are the consumables universal or proprietary?

The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.

Are options or configurations available?

The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.

Do you provide on-site installation?

Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.

What should be avoided when using the Automatic Oil Dielectric Tester?

Do not use the instrument outside its rated range or intended samples, skip calibration or ignore safety and maintenance instructions. Follow the operating manual and laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry