Color & Haze meter is used for haze and transmittance measurement. It has open measurement area with no limit on sample size, can carry out vertical measurements as well. It comes with different light sources such as A, C, D65 etc. for haze, transmittance measurement. Design confirms to & standards, where transmittance compensation measurement provides high accuracy test result.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Color & Haze meter has applications in haze and transmittance measurement of anti-glare plastic sheets, films, glass, panel screens used for TV screen, car navigation screen, computer screen, mobile phone cover & other transparent & semi-transparent material color.
Specifications
| Light source | -A,-C,Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,,U30,,,TL83,TL84 |
| Standards | D1003/D1044,ISO13468/ISO14782 & No.15, 7724/1, E1164 |
| Parameters | , Transmittance(T),Spectral Transmittance Whiteness Index ( , ,/ ,Hunter, Taube Berger Stensby)Yellowness Index ( D1925, , ) Tint( ), Metamerism Index, MilmAPHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00) |
| Spectral response | Luminosity function y |
| Wavelength | 400 to 700 nm |
| Wavelength interval | 10 nm |
| Geometry | 0/d |
| Measurement area/sample port | 16.5 mm/ 21 mm |
| Measurement range | 0 to 100 % |
| Haze resolution | 0.01 |
| Haze responsibility | ≤ 0.1 |
| Sample size | Thickness ≤ 145 mm |
| Display | 5.0 inch touch screen |
| Memory | 20000 value |
| Interface | |
| Power | 220 V with power cable |
| Working temperature | 0 to 45 °C, Relative humidity 80% or below (at 35 ° C), no condensation |
| Storage temperature | 0 to 50 °C |
| Dimension (L × W × H) | 598 × 247 × 366 mm |
Features
5.0 inch touch screen display interface
Different light sources A,C, D65 etc. for haze, transmittance measurement
Open measurement area with no limit on sample size
Confirms to & haze measurement standard
Equipped with software for haze and transmittance
Different parameters can be tested like Haze, Transmittance, and Yellowness & Whiteness Index etc.
Large storage capacity 100 test samples , 200 measurement records for each sample
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.