Introduction

Fluorometer is the next generation of benchtop dual-channel Fluorometer, features 460 ± 20 nm and 525 ± 20 nm excitation filter and measures dsDNA concentration with high sensitivity lower detection limit of 0.5 ng/ul. It offers blue and green channel fluorescence to measure fluorescence intensity of fluorescent reagent that combines with target molecule to read concentration of sample. Designed to accurately detect high-sensitive fluorescence while quantifying , , and protein. This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Fluorometer is used for processing scarce and difficult samples, for low quantity of , , or protein after extraction, also, in expensive experiments: q , cloning, transfection, the next generation sequencing and etc. Applied for Nucleic acid quantification, Plant reporter gene detection, Apoptosis detection.

Specifications

Dynamic range Five orders of magnitude
Linear dynamic range R2 >0.995
Processing time 3s (Once)
Light source Blue Green
Excitation filters 460 ± 20 nm 525 ± 20 nm
Emission filters 525 to 570 nm (45 nm) 575 to 640 nm (65 nm)
Detector Photodiode
Repeatability <1.5 %
Stability <1.5 %
Sensitivity ds : 0.5 ng/ml
Dimension 194 × 155 × 72.5 mm
Weight 0.4 kg

Features

Designed with 4.3 inch touch screen, small and easy to use

Easy measurement within 3 sec for , , and protein

High sensitivity lowest detection limit is 0.5 pg/ul

Linear dynamic range with five orders of magnitude

Equipped with two fluorescence channels for nucleic acid, protein quantitation in one detection

Offers opening system

Adopts tube adapter

It can save at most 1,000 data and output data by port

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.