Introduction
Plant Photosynthesis Meter offers CO₂ sensing capability, supporting concentration ranges and responsive leaf gas exchange monitoring. Initiated with adaptive LED light modulation, that ensures dynamic adjustment to varying ambient light conditions. Incorporated with temperature regulation and humidity control, maintains microenvironmental conditions within leaf chamber during data capture. It is built for long-duration field measurements with energy management, automated calibration support, firmware expandability. Meter supports physiological research, agricultural optimization by tracking real-time plant photosynthesis responses in varied settings.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
Plant Photosynthesis Meter supports plant physiology studies, environmental monitoring, and controlled greenhouse research. It is suitable for measuring leaf-level gas exchange in agriculture and ecological field trials.
Specifications
| CO₂ Measurement Range | 0 to 1500 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Measuring Accuracy | Avg noise Less than 0.4 ppm, Max Less than 0.8 ppm |
| CO₂ Response Time | 15 seconds |
| CO₂ Sensor Type | Non-dispersive infrared analyzer (NDIR) |
| Light Quantum Sensor Type | Silicon photocell with correction filter |
| Light Intensity Range | 0 to 2500 μmol/m²·s |
| Optical Spectrum Range | 400 to 700 nm (visible range) |
| Light Sensor Resolution | 1 μmol/m²·s |
| Light Sensor Error | ±2% |
| Leaf Temperature Sensor Type | T-type thermocouple, K-type thermocouple |
| Leaf Temperature Range | 0 to 50.0°C |
| Leaf Temperature Resolution | 0.1°C |
| Leaf Temperature Error | ±0.3°C |
| Air Temperature Sensor Type | Thermal resistor |
| Air Temperature Range | 0.0 to 50°C |
| Air Temperature Resolution | 0.1°C |
| Air Temperature Error | ±0.3°C |
| Humidity Range | 0.0 to 100.0% RH |
| Humidity Resolution | 0.1% |
| Humidity Error | ±1.5% RH |
| Humidity Response Time | 8 seconds |
| Flow Meter Type | Miniature electronic flow meter |
| Flow Rate Range | 0.0 to 1.0 L/min |
| Flow Resolution | 0.01 L/min |
| Flow Error | ±1% of reading |
| Light Source Type | LED white light |
| Pressure Range | 15.0 to 115.0 kPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Error | ±1.5% |
| Fluorescent Light Range | 0 to 3500 μmol/m²·s |
| Measuring Time | 1 to 10 seconds |
| Sampling Speed | 5 μs per reading |
| CO₂ Control Range | 0 to 5000 ppm |
| CO₂ Source | 12g CO₂ cylinder |
| Leaf Temp Control Precision | ±1°C |
| Cooling/Heating Element | Semiconductor temperature board |
| Humidity Control Range | RH 10% to 90% |
| Humidity Control Accuracy | ±3% |
| Working Temperature Range | 0 to 50°C |
| Working Humidity Range | 0 to 90% RH |
| Power Supply | 7.2 V 10.0 AH lithium battery; 8.4 V 2.0 A adapter |
| Light Emitting Area | 3.0 × 7.5 cm |
| CO₂ Cylinder Dimensions | Diameter: 8.5 mm, Height: 89 mm , Width: 22 mm |
| Leaf Temperature Chamber Dimensions | 250 × 250 mm |
| Dimensions | 280 × 245 × 160 mm |
| Fluorescent Module Dimensions | 25 × 90 × 50 mm |
| Fluorescent Module Weight | 200 g |
| Weight | 5.0 kg |
Features
Fast sensor response
Durable chamber grip
Quick leaf locking
Smooth sampling flow
Low noise reading
FAQs
1. What is the main function of this Plant Photosynthesis Meter?
It is a professional laboratory instrument designed for Plant Photosynthesis Meter applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Plant Photosynthesis Meter compared to similar products?
It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.
3. What regular maintenance is required for this Plant Photosynthesis Meter?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Plant Photosynthesis Meter?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Plant Photosynthesis Meter shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.