Introduction

Vertical Incubator Shaker provides speed range of 10 to 300 rpm. It operates from 4℃ to 60℃, suitable for both refrigerated and heated incubation. Its orbital shaking amplitude of φ26 mm ensures efficient and uniform mixing of samples. Its programmable timer allows controlled operation duration for time-sensitive procedures. Vertical Incubator Shaker is ideal for high-volume microbial cultivation, cell suspension, fermentation, enzyme reactions.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Vertical Incubator Shaker is ideal for microbial cultivation, cell suspension, fermentation, enzyme reactions, nucleic acid extraction, molecular biology and biochemical research.

Specifications

Volume 220L
Temperature Control Range 4℃ to 60℃
Ambient Temperature Range 5℃ to 30℃
Temperature Accuracy ±0.1℃
Temperature Uniformity ±0.5℃ at 37℃
Relative Humidity 20% to 80% RH
Speed Range 10 to 300 rpm
Speed Accuracy ±1 rpm
Shaking Amplitude φ26 mm
Capacity 100ml × 85, 250ml × 60, 500ml × 36, 1000ml × 21
Standard Configuration 500 ml × 32
Maximum Loading Capacity 18 kg
Timer Range 0 to 999.9 Hours
Power Consumption 550 W
Power Supply 220V, 50 to 60Hz
Platform Dimensions 540 × 490mm (×2)
Internal Dimensions 600 × 570 × 700 mm
External Dimensions 700 × 820 × 1270 mm
Net Weight 190 kg

Features

LCD touch screen

Flexible speed control 

Large Holding Capacity

Multi-Flask Compatibility

Streamlined structure

Model No.

Accessory Name

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (50ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (100ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (150ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (200ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (250ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (500ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (1000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (2000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (3000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (5000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

96 Micro Plate Holder

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Paste adhesive pad (20 × 20cm)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Spring Clamp(Small)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Spring Clamp(Large)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Tube rack clamp

FAQs

1. What is the main function of this Vertical Shaker?

It is a professional laboratory instrument designed for Vertical Shaker applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Vertical Shaker compared to similar products?

It incorporates advanced technologies including touch screen control, ensuring superior performance in terms of stability, accuracy, and operational convenience. The durable construction and strict quality control also guarantee long service life and low maintenance costs.

3. What regular maintenance is required for this Vertical Shaker?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Vertical Shaker?

Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.

5. What should I do if the Vertical Shaker shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.