Introduction

Moist Heat Sterilizers provide reliable and efficient sterilization for a wide variety of laboratory instruments and materials. They feature microprocessor-controlled temperature and pressure monitoring for precise operation and enhanced safety. These systems include automated fault diagnosis and valve controls for consistent performance and protection against overpressure. Their colored LCD touch screen provides clear visualization of operational steps and real-time status updates. moist heat sterilizers are ideal for clinical laboratories, hospitals, pharmaceutical labs, life sciences, and research institutions.

Moist Heat Sterilizer T-S211MSHS

Moist Heat Sterilizer T-S211MSHS


Moist heat sterilizer is a table top microprocessor control unit with continuous monitoring of pressure and voltage with temperature control. The colored LCD touch screen displays operati...

Standards

IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Complies with the above standards, but is not limited to them.

Features

1. Automatic air removal and drying improve sterilization results.

2. Vertical, horizontal and benchtop models suit various spaces.

3. Pre-set programs for liquids, wrapped goods, instruments and waste.

4. Stainless chamber resists corrosion and is easy to clean.

5. Cycle data can be archived for sterile-service traceability.

FAQ

What are the main applications of the Moist Heat Sterilizer?

The Moist Heat Sterilizer is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.

Which standards and regulations apply to the Moist Heat Sterilizer?

The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.

How long is the warranty period?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Will staff need special training?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Moist Heat Sterilizer need calibration or verification?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Are consumables and spare parts easy to obtain?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can the Moist Heat Sterilizer be customised?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What maintenance and safety points matter?

Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.