Introduction

Atomic Absorption Spectrophotometer features detection limit of less than 0.004 µg/ml for efficient analysis. Integrated with double beam system, it enhances stability and measurement consistency. Incorporates D2 and self-absorption background correction for improved signaling. Equipped with automated acetylene and airflow control, ensuring smooth operation. fully PC-controlled system offers advanced and compact design for seamless functionality.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Atomic Absorption Spectrophotometer is ideal for quantifying metal elements in environmental samples, food, pharmaceuticals, biological fluids, mining, agriculture, petrochemicals, and forensic analysis.

Specifications

Optical Type Double beam
Atomizer Flame atomizer
Monochromator Czerny-Turner type, focal length at 350mm
Wavelength Range 190 to 900 nm
Wavelength Accuracy ±0.15nm
Wavelength Repeatability ±0.05nm
Grating Holographic diffraction grating with 1800 lines/mm
Slits 0.1, 0.2, 0.4, 0.7, 1.4, 2.0nm
Lamp Holder Automated 8 lamp turret
Detector Wide range UV-sensitive photomultiplier tube
Reading Mode Transmittance(T), Absorbance(A), Concentration(C)
Photometric Range 0 to 125%, -0.1 to 3.00A
Static Baseline Drift (Cu) Less than 0.002A/30 min
Dynamic Baseline Drift Less than 0.004A/15min
Background Correction D2 and self-absorption
Characteristic Concentration Cu less than 0.035µg/ml
Detection Limit Cu less than 0.004µg/ml
Repeatability (Cu) RSD less than 0.5%
Acetylene Flow Control Auto 12 level
Air Flow Control Auto 4 level
Burner Head 100mm Titanium alloy burner for air/acetylene operation
Safety Protection Flame sensor, gas leak sensor, gas pressure sensor
Software RGWIN AAS software package
Analytical Method Flame AA, Flame AE, Hydride generation
Concentration Calculation Method Standard curve, Standard Addition, Interpolation
Repeated Measurement Times 1-30 times, Average, SD and RSD
QA/QC Function Correlation coefficient, SD & RSD
Communication Port Standard RS-232
Working Environment Temperature 10-35 °C, Humidity less than 85%
Power Supply 110/220V, 50/60Hz
Dimension(W×D×H) 850×650×550mm
Weight 100KG

Features

Titanium alloy self-adjusting burner

Auto-slit selection 

High-performance glass nebulizer

Corrosion-resistant premix chamber

Report printing

Vertical 8-lamp turret

Standard Accessories

FAQs

1. What is the main function of this Atomic Absorption Spectrophotometer?

It is a professional laboratory instrument designed for Atomic Absorption Spectrophotometer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Atomic Absorption Spectrophotometer compared to similar products?

It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.

3. What regular maintenance is required for this Atomic Absorption Spectrophotometer?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Atomic Absorption Spectrophotometer?

Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.

5. What should I do if the Atomic Absorption Spectrophotometer shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.