Introduction
Nano Particle Size Analyzer offers measurement range of 1 nm to 10000 nm. Incorporates electrophoretic light scattering technology to measure zeta potential and determine isoelectric point. Equipped with advanced dynamic light scattering technology that provides fast and high-resolution particle size analysis. Integrated with high-speed laser that ensures efficient and reliable testing. Analyzer is ideal for nanotechnology, pharmaceuticals, and materials science.
Calibrated according to national metrology standards, ensuring measurement accuracy and traceability. The instrument has passed CE certification, suitable for use in international markets.
Applications
Nano Particle Size Analyzer is employed for reliable particle size distribution analysis in industries such as pharmaceuticals, food, and materials science. It helps optimize product formulation and quality control by providing detailed insights into particle behavior.
Selection Guide
Nano Particle Size Analyzer is a versatile instrument designed for accurate measurement of particles ranging from 1 to 10,000 nm, making it suitable for various research studies and industrial applications involving nanomaterials. It is widely used in fields such as pharmaceuticals, biotechnology, environmental science, and chemical engineering for experiments including drug delivery development, polymer dispersion analysis, colloidal stability testing, and nanoparticle synthesis monitoring. With a concentration range of 0.1 mg/mL to 100 mg/mL (or 0.1 mg/L to 100 mg/L), it supports diverse sample types. Its high electrophoretic mobility range of ≥±20 μm·cm/V·s and maximum conductivity of 200 mS/cm make it suitable for zeta potential and electrophoretic studies. Certified to meet international quality standards, this model ensures reliable performance and accuracy, making it a valuable selection for professionals seeking a high-performance particle size analysis solution.
Specifications
| Measure Range | 1 to 10000nm |
| Concentration Range | 0.1mg/ml~100mg/ml |
| Electrophoretic Mobility Range | ≥±20μm.cm/V.s |
| Highest Conductivity | 200mS/cm |
| Accuracy Error | |
| Repeatability Error | |
| Laser | Semiconductor laser |
| Laser Wavelength | 635nm |
| Detector | Photomultiplier tube |
| Scattering Angle | 18ºC 90ºC |
| Temperature Range | 5ºC to 45°C |
| Temperature Control Accuracy | 0.1°C |
| Test Speed | |
| Digital Correlator (Auto-correlation Channels) | 892 |
| Baseline Channel | 4 |
| Physical Channels | 5000 |
| Unit Delay Time | 1μs to 10ms |
| Laser Power | 1 to 40mw |
| Sample Volume | 10mm×10mm×40mm, 1-4mL 10mm×10mm×60mm, 1mL |
| Outer Dimension | 560mm×450mm×300mm |
| Net Weight | 20Kg |
Features
Advanced particle size analysis
Wide measurement range
Real-time data processing
User-friendly interface
Multiple dispersion units
Laser diffraction technology
Compact and versatile design
Standard Accessories
FAQs
1. What is the main function of this Nano Particle Size Analyzer?
It is a professional laboratory instrument designed for Nano Particle Size Analyzer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Nano Particle Size Analyzer compared to similar products?
It provides high measurement accuracy, fast analysis speed, and good repeatability. The automatic calibration and self-diagnostic functions reduce human error and ensure reliable test results for critical applications.
3. What regular maintenance is required for this Nano Particle Size Analyzer?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Nano Particle Size Analyzer?
Installation requirements include: 1) Selecting a vibration-free location to ensure measurement accuracy; 2) Providing stable power supply with voltage regulation if necessary; 3) Ensuring proper ventilation for instruments requiring gas exhaust; 4) Maintaining appropriate ambient temperature (usually 5-40℃) and humidity (≤85%) as specified in the operating manual.
5. What should I do if the Nano Particle Size Analyzer shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.