Introduction

Flow Cytometer detects cellular particles from 0.2 μm to 60 μm for a thorough analysis of various cell types and sizes. unit is equipped with lasers emitting light at wavelengths of 488nm and 638nm for multiparameter analysis. Operates at a rapid rate of 45,000 events per second and can analyze 96-well plates within 30 minutes. Enhanced with an Avalanche Photodiode Detector (APD) for precise and accurate detection.

Applications

Flow Cytometer is widely used in immunophenotyping, cell cycle analysis, drug discovery, and hematology.

Specifications

Wavelength488nm, 638nm
LaserSemiconductor laser
Laser Power488 nm & 638 nm laser: 20mW
40/60mW (Optional)
Fluorescence Channels6
Filters Configuration488nm laser: 530/30 nm BP FITC, 585/42 nm BP PE, 700 BP Per CP/ PE-Cy 5, 785/55 nm BP PE-Cy7
638nm laser: 660/20 nm BP APC, 785/55 nm BP APC-Cy7
OpticsThe excitation and receiving of solid spatial separation. No fiber conduction. Fixed optical path.
Sensitivity of FluorescenceFITC < 75 MESF
PE < 55 MESF
APC < 55 MESF
FSC Sensitivity0.5 μm
SSC Sensitivity0.2 μm
Range of Particles0.2 μm to 60 μm
Linear≥ 0.98
ResolutionCV ≤2%
Carry-Over≤ 0.1%
DetectorAvalanche Photodiode Detector(APD)
Speed45,000 events/s; 96 - well plates/30min
Minimum Sample Volume10μL
Speed of Sample15 to 235 μL/Min
Absolute CountVolumetric method: Microspheres method
Preheating Time<4min
Blending ModeWhole plate; single pipe; interval mixing is set freely
Tube Numbers of Loader40 tubes and 96 holes
Type of TubeStandard flow pipe(12 × 75mm, 5ml)
96 - well plates(F,U,V type)
Centrifugal tube (1.5ml, 2ml)
Capacity of Liquid BottleWaste liquid barrel 6L,Sheath liquid drum 6L,Cleaning liquid drum 1L
Maintenance SystemLiquid path maintenance automation
SoftwareSoftware has an edition in English and Chinese
With the function of automatic quality control detection, the software can draw the Levey-Jennings curve automatically
Support to be connected with clinical LIS software, to facilitate data graphic transmission
Feature of SoftwareAutomatic saving mode against power failure
Detection and analysis can run at the same time
CompensationCompensation Matrix List
Quick Compensation
Auto Compensation
Auto Compensation Calculation
FCS FormatFCS 3.0
Operational Environment10 °C to 35 °C, 15 to 80 % RH
Computer Operating SystemWin10 pro
Voltage220 V, 50Hz
Dimension (W × D × H )The host system: 44 × 43.5 × 52 cm
The host system with leader: 57.2 × 53.3 ×52 cm
Liquid tray: 44 × 32 × 45 cm
Liquid Tray Weight7 Kg
Host System Weight32 Kg
Host System with Leader Weight38 Kg

Features

Simultaneous detection and analysis capability

Supports Clinical LIS integration

Liquid pathway automation for efficiency

Offers multiple CD Markers

Autonomous power-failure saving mode

FAQ

Q1: What is the main application of this laboratory equipment?
A1: It is mainly used for general laboratory sample processing in laboratory settings, such as sample preparation, analysis, or processing.

Q2: Does the product come with a warranty?
A2: Yes, it provides a 1-year warranty for the main unit (excluding consumable parts), covering manufacturing defects and quality issues.

Q3: Is installation required after receiving the product?
A3: No, it is ready to use after unpacking. Simply connect the power supply (confirm the voltage matches) and follow the operation manual.

Q4: What are the power supply requirements?
A4: It supports AC 220V/50Hz or 110V/60Hz (selectable based on region), please confirm the voltage specification before use.

Q5: How to get technical support if there is a problem?
A5: You can contact our technical support team via email or phone. We provide online troubleshooting guidance and on-site service if needed.